background image

Premier Elite 5Ci-W Internal

 

Installation Manual 

INS655-3 

LED Indications 

The 

Premier Elite 5Ci-W

 LED’s aid in the installation of the device and act as status indicators. The table below details the status of  each 

LED indicator.  

 

T

he LED jumper has no effect on the status described below.

 

Leds  

Status  

Left LED flashing quickly  

Device is attempting to communicate with receiver after power up.  

Left LED flashing slowly  

Device has learnt or re-connected to receiver and is waiting for the tamper to be 

closed.  

Both LEDs off  

Device  has  failed  to  learn  or  failed  to  communicate  after  tamper  has  been 

closed.  

Right LED flashing quickly  

Device  is  attempting  to  communicate  with  receiver  after  tamper  has  been 

closed.  

Right LED on solid (for 3 seconds)  

Device has successfully connected with receiver after tamper closed.  

Right LED flashing slowly  

Hold-off mode has been requested from the panel but the tamper is closed. Bell 

will not self-activate. Cancels after 20 minutes.  

LEDs alternating quickly.  

Device  has  successfully  connected  with  receiver  after  tamper  closed  and  self-

activation on tamper will re-activate in 2 minutes.  

Both LEDs flashing 

1 or 2 batteries are fitted incorrectly. Remove the batteries and reinstall correctly. 

Hold-Off Mode 

For safety reasons, each Texecom sounder and strobe unit incorporates a unique patented engineer Hold-Off mode. This mode prevents 

the unit from self-activating during installation and maintenance, thereby allowing only bona fide engineers access to the unit without any 

loss of tamper protection. The sounder can be put in hold-off mode by flashing the strobe 3 times, or by pressing the Omit key when in Bell 
Test menu. 

When the outer cover is replaced and the tamper circuit is closed, the LEDs will alternate rapidly, confirming that the tamper circuit is secure 

and signalling that self activation on tamper will be re-enabled within 2 minutes, after which the LEDs will alternate slowly to signal normal 

operation. If the tamper circuit is re-opened within the 2 minute period, then hold-off mode will be restored. 

 

The LED's will only flash after hold off mode has stopped IF the LED jumper is in the "ON" position. 

 

The strobe is disabled during hold-off mode. Hold-off mode is immediately cancelled when the sounder is activated from the control panel if the 

tamper is closed.

.

 

Tamper Detection 

As this  unit is designed for internal applications only  and may be mounted at low level  and within easy reach the SAB  facility  has been 
disabled. The unit 

WILL NOT

 self activate in the case of the device being tampered.  

Care should be taken when installing these devices, and all possible precautions should be taken to ensure the units are not easily 

accessible to unauthorised persons. 

Tamper signals will still be generated and logged by the control panel. Tamper signals will also be transmitted to the ARC if signalling is 
enabled.  

Mounting the Unit 

Select a suitable position to mount the unit, which satisfies the following criteria: 

 

Good wireless signal  

 

The  wireless  signal  may  be  checked  before  final  installation  by  depressing  the  tamper  switch  briefly.  The  Right  LED  will  flash  to  indicate 

communication and will the go solid for 3 seconds to indicate a successful connection.  

 

Highly prominent for maximum deterrence 

 

High enough to be out of normal reach to deter tampering. See above 

In addition to the corner screw fixing points, the unit also has a central keyhole to simplify mounting and aid levelling. 

Four screws and wall plugs are required for mounting the backplate to an even surface.  

 

An  additional screw  is  required  to  provide  "Removal  from  Mounting"  tamper  and  is required in installations complying  with  the  requirements PD6662 

and/or  EN50131.  In  doing  so,  care  must  be  taken  to  leave  the  screw  head  slightly  proud  to  ensure  that  the  microswitch  remains  level  and  closes 
correctly when the outer cover is fitted. 

Содержание Premier Elite 5Ci-W

Страница 1: ...Premier Elite 5Ci W Installation Manual INS655 3 ...

Страница 2: ...T self activate in the case of the device being tampered System Compatibility The Premier Elite 5Ci W is compatible with all Premier Elite control panels V2 11 and later and Premier Elite 8XP W Premier Elite 32XP W Ricochet Monitor V2 18 2 or later should also be used Battery Pack The battery pack is retained by a reusable cable tie and should be secured through the holes in the backplate above th...

Страница 3: ...Learning the Sounder As with all Ricochet enabled devices the sounder should be learned to the control panel along with all other devices BEFORE it is installed in it s final location The Premier Elite 5Ci W is learned to a Zone on the control panel in the same way that Ricochet enabled detection devices are The Zone type and Ricochet Device Mode is automatically assigned based on the type of devi...

Страница 4: ...activation on tamper will be re enabled within 2 minutes after which the LEDs will alternate slowly to signal normal operation If the tamper circuit is re opened within the 2 minute period then hold off mode will be restored The LED s will only flash after hold off mode has stopped IF the LED jumper is in the ON position The strobe is disabled during hold off mode Hold off mode is immediately canc...

Страница 5: ...ironmental Protection N A Brightness 100mcd typical Flash Rate tamper secure 1 4 sec flash at 5 sec intervals alternating typical Wireless Frequency 868 0MHz 868 6MHz Operating Temperature 25 C 13 F to 55 C 131 F Storage Temperature 25 C 13 F to 60 C 140 F EMC Environment Residential Commercial Light Industrial Industrial The flash rate will reduce to 0 125Hz after flashing for 20 minutes 1 flash ...

Страница 6: ...e in systems designed to comply with EN 50131 4 EN50131 5 3 and PD6662 at Grade 2 and Environmental Class II Security Grade 2 Environmental Class 2 EN Standard Premier Elite 5Ci W EN60950 1 EN61000 6 3 EN 301 489 3 EN50130 4 EN300 220 1 EN50131 1 EN50130 5 EN50131 5 3 EN50131 6 PD6662 EN50131 4 Warranty All Texecom products are designed for reliable trouble free operation Quality is carefully moni...

Страница 7: ...Premier Elite 5Ci W Internal Installation Manual INS655 3 7 Notes ...

Страница 8: ...shire BB4 4PW England Technical Support UK Customers Tel 08456 300 600 Calls charged at 3 36 pence per minute from a BT landline Calls from other networks may vary International Customers Tel 44 1706 233875 Email techsupport texe com Texecom Limited 2015 INS655 3 ...

Отзывы: