Installation
Premier 24
Installation Manual
22
INS248
Triple End Of Line (TEOL)
Use this wiring configuration when connecting PIR devices
with that require Anti Mask and Fault detection. Several
zone wiring programming options are available for this,
Triple EOL is illustrated below.
1 Normally Closed Device
with Fault and Mask
(Mask = Fault + Alarm)
E.O.L
Alarm
T
A
Zone 1
4k7
W
2k2
W
Tamper
Fault
2k2
W
Alarm contact resistor = 4K7
Fault contact resistor = 2K2
EOL resistor = 2K2
!
When using this configuration, only 1 detector can be
connected to each zone.
!
Alternative resistor values are available – see
Zone
Wiring Types
on page 37 for more details.
Auxiliary Tamper Connections
The Auxiliary Tamper terminals allow the control panel to
monitor the tamper loops of external devices such as power
supplies etc.
!
If the ‘Auxiliary Tamper’ terminals are not being used
they must be linked out.
Speaker Connections
This output can be used for driving up to one 16
Ω
or two 8
Ω
loudspeakers as shown below:
Tamp
Strb 0V
Bell+12V
PG 1 SPK -
Tamp
Strb 0V
Bell+12V
PG 1 SPK -
!
For details on testing Speaker outputs, see page 79
Содержание Premier 24
Страница 1: ...Issue 3 Premier 24 Installation Manual ...
Страница 90: ...Notes Premier 24 Installation Manual 90 INS248 ...
Страница 91: ...Premier 24 Installation Manual Notes INS248 91 ...