Texecom Odyssey 1E Скачать руководство пользователя страница 16

INS154-7 16/17

following directives:

2004/108/EC    EMC Directive
2006/95/EC      LVD Directive
2011/65/EU      RoHS Directive

The product therefore meets all the requirements to enable it to be CE marked.

Weee Directive: 2012/19/EU (WEEE directive): Products marked with this symbol
cannot be disposed of as unsorted municipal waste in the European Union. For
proper recycling, return this product to your local supplier upon the purchase of
equivalent new equipment, or dispose of it at designated collection points. For
more information see: www.recyclethis.info.

These product are Type B Moveable devices and is suitable for use in systems
designed to comply with EN 50131-1, EN50131-4 and PD6662 at Grade 2 & 3 and
Environmental Class IV. All E Models are Grade 2 and all non E Models are Grade 3.

6.0 Warranty

All Texecom products are designed for reliable, trouble-free operation. Quality is
carefully monitored by extensive computerised testing. As a result the Premier
Odyssey 1E, 2E, 3E, 4E, 5E 
and 5E Compact are covered by a two year warranty
against defects in material or workmanship (details on request).

The Premier Elite Odyssey 12, 3, 4, 5, and 5 Compact are covered by a five year
warranty.

Because the Premier & Premier Elite Odyssey  Series are not complete alarm
systems but only a part thereof, Texecom cannot accept responsibility or liability
for any damages whatsoever based on a claim that a unit failed to function
correctly. Due to our policy of continuous improvement Texecom reserve the right
to change specification without prior notice.

Odyssey is a trademark of Texecom Ltd.

Premier & Premier Elite are trademarks of Texecom Ltd

Содержание Odyssey 1E

Страница 1: ...Odyssey Series Installation Manual INS154 7...

Страница 2: ...e Unit 3 1 2 Mounting the Unit 4 1 3 Adjusting Tamper Sensitivity 4 1 4 Wiring The Unit 5 1 5 Grade 3 Wiring 6 1 6 Installing Multiple Units 8 1 7 Commissioning 9 2 0 Servicing 10 3 0 Safety 12 4 0 Te...

Страница 3: ...INS154 7 3 17 1 0 Installation 1 1 Accessing The Unit...

Страница 4: ...ckplate to an even surface An additional screw may be required to provide wall tamper by tting through the screw hole next to the dual tamper microswitch In doing so care must be taken to leave the sc...

Страница 5: ...st input for enabling remote test via Maintex or Wintex or any supporting panel Tamper Relay Negative Removed on Tamper Input and reports Tamper when there is a power loss to the sounder Fault Relay R...

Страница 6: ...rapidly con rming that the tamper circuit is secure and signalling that S A on tamper will be re enabled within 2 minutes after which the LEDs will alternate slowly to signal normal operation If the t...

Страница 7: ...ss On completion of a successful test the Fault relay will close if the test fails the relay will stay open Optional Battery First Connection Method Hold O mode automatically cancels when both the tam...

Страница 8: ...stallation the current demand may exceed the rated current output of the control panel This can be avoided by selecting Low Current LC or SCB mode on one or more of the connected units Low Current Mod...

Страница 9: ...ry only the right LED will ash quickly to signal that the unit cannot self activate until power has been supplied from the control panel N When selecting SCB mode the battery must be connected before...

Страница 10: ...the strobe three times within 30 seconds Most control panels have a method of testing the strobe which should be utilised Failing this the strobe can be manually activated by connecting the S STRB wi...

Страница 11: ...e period then Hold O mode will be restored N If Hold O mode is invoked but the tamper circuit is not opened or remote power is not removed within 15 minutes then Hold O will automatically start to can...

Страница 12: ...t of the PCB labelled Warning High Voltage 3 The unit incorporates software which disables the strobe whilst the tamper switch remains open This is a safety feature and cannot be disabled The piezo dr...

Страница 13: ...pply Voltage 12 16 VDC 13 7 nominal E Models 109dB Peak at 1m A Weighting 90 Current Drain typical at 13 7VDC Non E Models 115dB Peak at 1m A Weighting 90 Quiescent 18mA Acoustic Output Varying Sound...

Страница 14: ...ypical Discharge Time 60VDC 180 seconds Comfort LEDs Brightness 100mcd typical Flash Rate tamper secure 1Hz alternati ng typical The ash rate will reduce to 0 125Hz after ashing for one hour 1 ash eve...

Страница 15: ...lid and internal steel cover 5C 5EC 950g 34oz approx All other models Wall and lid Dimensions h x w x d 1 1E 318mm x 201mm x 66 5mm 2 2E 242mm x 382mm x 76mm 3 3E 3M 315mm x 306mm x 78mm 4 4E 310mm x...

Страница 16: ...al Class IV All E Models are Grade 2 and all non E Models are Grade 3 6 0 Warranty All Texecom products are designed for reliable trouble free operation Quality is carefully monitored by extensive com...

Страница 17: ...INS154 7 17 17...

Отзывы: