2.0 Servicing
Most control panels have a method of testing the siren and strobe, which should be
utilised. Failing this, simply arm the system and cause an alarm to confirm correct
operation. Temporarily disconnect the positive supply to the unit at the control
panel to confirm that the sounder self-activates.
N
The strobe does not self-activate.
N
Some control panels have an option to select the sounder cut-off time.
The unit will sound for either 15 minutes or for the panel cut-off time,
whichever is the shorter.
For safety reasons if it is necessary to inspect the unit, the Self-Activate (S/A)
function should be disabled before the cover is opened or remote power removed.
This is achieved by using the unit’s unique patented engineer Hold-Off mode. This
is invoked by activating and de-activating the strobe three times within 30
seconds. Most control panels have a method of testing the strobe, which should be
utilised. Failing this the strobe can be manually activated by connecting the S
(STRB) wire to 0V at the control panel. Hold‑Off mode is shown to be active with
the tamper circuit secure by the right LED only flashing.
If the tamper circuit is not opened or remote power not removed, then Hold-Off
mode will automatically start to cancel after 15 minutes, indicated by the LEDs
alternating rapidly to signal that S/A on tamper and remote power loss will be re-
enabled within a further 2 minutes.
Once the outer cover is removed the left LED only will flash to indicate that the
tamper circuit is open. If remote power is removed, and the tamper circuit is left
closed, the right LED with flash rapidly to indicate that the unit is on standby
battery power.
When the tamper circuit is closed or remote power re-applied, the LEDs will
alternate rapidly, confirming that the tamper circuit is secure, remote power is