background image

ADDITIONAL TERMS AND CONDITIONS, WARNINGS, RESTRICTIONS, AND DISCLAIMERS FOR

EVALUATION MODULES

Texas Instruments Incorporated (TI) markets, sells, and loans all evaluation boards, kits, and/or modules (EVMs) pursuant to, and user
expressly acknowledges, represents, and agrees, and takes sole responsibility and risk with respect to, the following:

1.

User agrees and acknowledges that EVMs are intended to be handled and used for feasibility evaluation only in laboratory and/or
development environments. Notwithstanding the foregoing, in certain instances, TI makes certain EVMs available to users that do not
handle and use EVMs solely for feasibility evaluation only in laboratory and/or development environments, but may use EVMs in a
hobbyist environment. All EVMs made available to hobbyist users are FCC certified, as applicable. Hobbyist users acknowledge, agree,
and shall comply with all applicable terms, conditions, warnings, and restrictions in this document and are subject to the disclaimer and
indemnity provisions included in this document.

2.

Unless otherwise indicated, EVMs are not finished products and not intended for consumer use. EVMs are intended solely for use by
technically qualified electronics experts who are familiar with the dangers and application risks associated with handling electrical
mechanical components, systems, and subsystems.

3.

User agrees that EVMs shall not be used as, or incorporated into, all or any part of a finished product.

4.

User agrees and acknowledges that certain EVMs may not be designed or manufactured by TI.

5.

User must read the user's guide and all other documentation accompanying EVMs, including without limitation any warning or
restriction notices, prior to handling and/or using EVMs. Such notices contain important safety information related to, for example,
temperatures and voltages. For additional information on TI's environmental and/or safety programs, please visit

www.ti.com/esh

or

contact TI.

6.

User assumes all responsibility, obligation, and any corresponding liability for proper and safe handling and use of EVMs.

7.

Should any EVM not meet the specifications indicated in the user’s guide or other documentation accompanying such EVM, the EVM
may be returned to TI within 30 days from the date of delivery for a full refund. THE FOREGOING LIMITED WARRANTY IS THE
EXCLUSIVE WARRANTY MADE BY TI TO USER AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED, IMPLIED, OR
STATUTORY, INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE. TI SHALL
NOT BE LIABLE TO USER FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES RELATED TO THE
HANDLING OR USE OF ANY EVM.

8.

No license is granted under any patent right or other intellectual property right of TI covering or relating to any machine, process, or
combination in which EVMs might be or are used. TI currently deals with a variety of customers, and therefore TI’s arrangement with
the user is not exclusive. TI assumes no liability for applications assistance, customer product design, software performance, or
infringement of patents or services with respect to the handling or use of EVMs.

9.

User assumes sole responsibility to determine whether EVMs may be subject to any applicable federal, state, or local laws and
regulatory requirements (including but not limited to U.S. Food and Drug Administration regulations, if applicable) related to its handling
and use of EVMs and, if applicable, compliance in all respects with such laws and regulations.

10. User has sole responsibility to ensure the safety of any activities to be conducted by it and its employees, affiliates, contractors or

designees, with respect to handling and using EVMs. Further, user is responsible to ensure that any interfaces (electronic and/or
mechanical) between EVMs and any human body are designed with suitable isolation and means to safely limit accessible leakage
currents to minimize the risk of electrical shock hazard.

11. User shall employ reasonable safeguards to ensure that user’s use of EVMs will not result in any property damage, injury or death,

even if EVMs should fail to perform as described or expected.

12. User shall be solely responsible for proper disposal and recycling of EVMs consistent with all applicable federal, state, and local

requirements.

Certain Instructions.

User shall operate EVMs within TI’s recommended specifications and environmental considerations per the user’s

guide, accompanying documentation, and any other applicable requirements. Exceeding the specified ratings (including but not limited to
input and output voltage, current, power, and environmental ranges) for EVMs may cause property damage, personal injury or death. If
there are questions concerning these ratings, user should contact a TI field representative prior to connecting interface electronics including
input power and intended loads. Any loads applied outside of the specified output range may result in unintended and/or inaccurate
operation and/or possible permanent damage to the EVM and/or interface electronics. Please consult the applicable EVM user's guide prior
to connecting any load to the EVM output. If there is uncertainty as to the load specification, please contact a TI field representative. During
normal operation, some circuit components may have case temperatures greater than 60°C as long as the input and output are maintained
at a normal ambient operating temperature. These components include but are not limited to linear regulators, switching transistors, pass
transistors, and current sense resistors which can be identified using EVMs’ schematics located in the applicable EVM user's guide. When
placing measurement probes near EVMs during normal operation, please be aware that EVMs may become very warm. As with all
electronic evaluation tools, only qualified personnel knowledgeable in electronic measurement and diagnostics normally found in
development environments should use EVMs.

Agreement to Defend, Indemnify and Hold Harmless.

User agrees to defend, indemnify, and hold TI, its directors, officers, employees,

agents, representatives, affiliates, licensors and their representatives harmless from and against any and all claims, damages, losses,
expenses, costs and liabilities (collectively, "Claims") arising out of, or in connection with, any handling and/or use of EVMs. User’s
indemnity shall apply whether Claims arise under law of tort or contract or any other legal theory, and even if EVMs fail to perform as
described or expected.

Safety-Critical or Life-Critical Applications.

If user intends to use EVMs in evaluations of safety critical applications (such as life support),

and a failure of a TI product considered for purchase by user for use in user’s product would reasonably be expected to cause severe
personal injury or death such as devices which are classified as FDA Class III or similar classification, then user must specifically notify TI
of such intent and enter into a separate Assurance and Indemnity Agreement.

Содержание UCD3138A64CEVM-660

Страница 1: ...lloscope 7 6 Equipment Setup 8 6 1 Graphical User Interface GUI 8 6 2 Hardware Setup 8 6 3 List of Test Points 9 7 Test Procedure 10 7 1 Download Firmware Code to UCD3138A64EVM 660 10 7 2 Erase Firmware Code from UCD3138A64EVM 660 11 7 3 Equipment Shutdown 11 8 EVM Assembly Drawing and PCB layout 12 9 Bill of Materials 15 Appendix A Summary of Using Code Composer Studio v5 5 17 List of Figures 1 U...

Страница 2: ...O 30 43 ADC12 Inputs 14 15 For additional device information see http www ti com product ucd3138a64 The UCD3138A64CEVM 660 is similar to the UCD3138CC64EVM 030 The UCD3138A64CEVM 660 is used either as a stand alone control card to study the UCD3138A64 controller IC or as a DPWM controller board working with a power stage board to implement a fully regulated power converter To help the targeted off...

Страница 3: ... power converters 2 Mbit SPI and I2C accessible EEPROMs for additional onboard memory storage capacity JTAG connector LED indicator PMBus connector to PC computer connection through USB to GPIO adapter Rich test points to facilitate the IC evaluation system design and circuit and firmware debugging 2 3 Configuring the EVM to Access EEPROM SPI or I2 C Communication with UCD3138A64 The UCD3138A64CEV...

Страница 4: ...ircuit 3 27 3 30 3 32 VDC use Connector J4 3 3 V connection to Port to use on board 3 3 VDC to bias or receive bias from PMBus 3 25 3 30 3 32 VDC PMBus Connector J5 PMBus Connection to USB to GPIO pin definition refer to TI PMBus connector Standard standard USB to GPIO document SLLU093 JTAG Standard JTAG communication connection Standard Connector J6 JTAG Standard JTAG communication connection Sta...

Страница 5: ... 21 23 25 27 29 31 33 35 37 39 16 18 20 22 24 26 28 30 32 34 36 38 40 J1 AGND AD00 AD01 AD02 AD03 AD04 AD05 AD06 AD07 AD08 AD09 AD10 AD11 AD12 AD13 AD14 EAP0 EAP1 EAP2 EAN0 EAN1 EAN2 1 2 3 4 5 6 7 8 9 10 J5 1 2 J4 V33D 0 R23 0 R27 DNP 0 R25 DNP 0 R26 DNP 0 R24 DNP 100 R28 D2 BAT54A 7 F D3 BAT54A 7 F DGND 100 R22 100 R20 100 R21 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 17 19 21 23 25 27 29 31 33 35 37 3...

Страница 6: ...te and test your design implementation to confirm the system functionality for your application Not in version control SVN Rev PWR660 Number Rev A LOGO PCB Texas Instruments FID2 DNP FID1 DNP FID3 DNP PWR660 A PCB Number PCB Rev Assembly Note ZZ2 These assemblies are ESD sensitive ESD precautions shall be observed Assembly Note ZZ3 These assemblies must be clean and free from flux and all contamin...

Страница 7: ... to GPIO adaptor visit http www ti com tool usb to gpio 5 1 2 1 USB to GPIO Interface Adapter Accessories including USB interface adapter HPA172 USB cable 5 pin B Mini Male to Type A Male Ribbon cable socket to socket 10 pin 2 headers polarized Figure 3 USB to GPIO Interface Adapter HPA172 5 2 Oscilloscope An analog or digital oscilloscope capable of 200 MHz bandwidth with appropriate accompanying...

Страница 8: ...M 660 board is launched with the following steps Click the Windows Start click All Programs click Texas Instruments Fusion Digital Power Designer click Device GUIs click UCD3xxx and UCD9xxx Device GUI 6 2 Hardware Setup 6 2 1 Setup Overview Figure 4 shows the connection between UCD3138A64EVM 660 and the PC computer through USB to GPIO Interface Adapter USB Adapter Connection Connect one end of the...

Страница 9: ...ated channel 2B TP32 DPWM3A Digital pulse width modulated channel 3A TP33 DPWM3B Digital pulse width modulated channel 3B TP34 GPIOA General purpose I O pin A TP35 GPIOB General purpose I O pin B TP36 GPIOC General purpose I O pin C TP37 GPIOD General purpose I O pin D TP38 PWM0 Pulse width modulated channel PWM2 TP39 PWM1 Pulse width modulated channel PWM2 TP40 12V_EXT External 12 VDC input to 3 ...

Страница 10: ...window appears as shown in Figure 6 Click Select File and browse an intended firmware code file with file extension x0 for example cycloneA64 x0 then click Download The firmware of cycloneA64 x0 is downloaded to the UCD3138A64 device on the UCD3138A64CEVM 660 EVM When prompted click Yes to complete the download Click Close to exit the download window 5 After the firmware code downloads to the UCD3...

Страница 11: ... steps and referencing Figure 6 1 Click Device ID 2 Click Command Program to jump to ROM SendByte 0xD9 3 Click Erase Set PFlash 0xFF 7 3 Equipment Shutdown 1 Exit the GUI 2 Disconnect the USB cable and the ribbon cable 11 SLUUB53 July 2014 Control Card in Digitally Controlled Off Line Isolated Power Converters Submit Documentation Feedback Copyright 2014 Texas Instruments Incorporated ...

Страница 12: ... x W 3 400 in x 1 965 in PCB material FR4 or compatible four layers and 1 oz copper on each layer Figure 7 UCD3138A64EVM 660 Top Layer Assembly Drawing Top View Figure 8 UCD3138A64EVM 660 Bottom Assembly Drawing No Components 12 Control Card in Digitally Controlled Off Line Isolated Power Converters SLUUB53 July 2014 Submit Documentation Feedback Copyright 2014 Texas Instruments Incorporated ...

Страница 13: ...CD3138A64EVM 660 Top Copper Top View Figure 10 UCD3138A64EVM 660 Internal Layer 1 Top View 13 SLUUB53 July 2014 Control Card in Digitally Controlled Off Line Isolated Power Converters Submit Documentation Feedback Copyright 2014 Texas Instruments Incorporated ...

Страница 14: ...D3138A64EVM 660 Internal Layer 2 Top View Figure 12 UCD313A64CEVM 660 Bottom Copper Top View 14 Control Card in Digitally Controlled Off Line Isolated Power Converters SLUUB53 July 2014 Submit Documentation Feedback Copyright 2014 Texas Instruments Incorporated ...

Страница 15: ...tions Right Angle J3 J4 2 Header 100mil 2x1 Tin plated TH Header 2 PIN 100mil Tin PEC02SAAN Sullins Connector Solutions J5 1 Header shrouded 100mil 5x2 Gold TH 5x2 Shrouded header 5103308 1 TE Connectivity J6 1 Header 100mil 7x2 Tin plated TH Header 7x2 100mil Tin PEC07DAAN Sullins Connector Solutions LBL1 1 Thermal Transfer Printable Labels PCB Label 0 650 H x 0 200 W THT 14 423 10 Brady 0 650 W ...

Страница 16: ... Texas Instruments PACKAGED 80mA LDO LINEAR REGULATORS DRB0008A U2 1 UCD3138A64PFC PFC0080 PFC0080A UCD3138A64PFC Texas Instruments U3 1 2 Mbit DataFlash with Extra 64 Kbits 1 65V Minimum SOIC 8 AT45DB021E SSHN B Adesto Technologies SPI Serial Flash Memory SOIC 8 U4 1 IC EEPROM 2MBIT 1MHz 8SOIC SOIC 8 M24M02 DRMN6TP STMicroelectronics C23 C24 0 10pF CAP CERM 10pF 50V 5 C0G NP0 0603 0603 C0603C100J...

Страница 17: ... this user s guide A 1 Importing a CCSv5 Project Upon running CCSv5 5 for the first time the Workspace Launcher window appears as shown in Figure 13 The user decides whether or not to use a workspace where it is located or to check the box that says Use this as the default and do not ask again For this guide a workspace is not used so click OK Figure 13 CCSv5 5 Workspace Launcher 17 SLUUB53 July 2...

Страница 18: ...ry click Browse navigate to the target project and click OK For this example the project is called Training_CCSv5 5 and is located in a folder called Training_CCS5v5 Check the box next to the discovered project and do not check Copy projects into workspace or Automatically import referenced projects Click Finish Figure 15 Importing a CCSv5 5 Project 18 Summary of Using Code Composer Studio v5 5 SL...

Страница 19: ...and shown in the Project Explorer as shown in Figure 16 At this point files in the project can be edited as required Figure 16 Project Explorer 19 SLUUB53 July 2014 Summary of Using Code Composer Studio v5 5 Submit Documentation Feedback Copyright 2014 Texas Instruments Incorporated ...

Страница 20: ... named directory must be renamed temporarily during this first build This allows the new ARM library to be built properly After this first build the CYGWIN directory can be rolled back to its original name and future builds can compile successfully Builds may take up to a minute or longer to compile for a first time build Figure 17 shows the state of a successful build Figure 17 Successful Build o...

Страница 21: ...r GUI for Isolated Power Applications User Guide for UCD3138 UCD3138064 UCD3138A64 applications SLUA676 6 Code Composer Studio v5 Wiki Texas Instruments http processors wiki ti com index php Category Code_Composer_Studio_v5 7 Converting UCD3138 Firmware Project from Code Composer Studio Version 3 3 to 5 2 SLUA679 8 UCD3138A64 Programmer s Manual SLUUB54 21 SLUUB53 July 2014 Summary of Using Code C...

Страница 22: ...ndling and use of EVMs and if applicable compliance in all respects with such laws and regulations 10 User has sole responsibility to ensure the safety of any activities to be conducted by it and its employees affiliates contractors or designees with respect to handling and using EVMs Further user is responsible to ensure that any interfaces electronic and or mechanical between EVMs and any human ...

Страница 23: ...This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at its own expense FCC Interference Statement ...

Страница 24: ...érieur au gain maximal indiqué sont strictement interdits pour l exploitation de l émetteur Mailing Address Texas Instruments Post Office Box 655303 Dallas Texas 75265 Copyright 2014 Texas Instruments Incorporated spacer Important Notice for Users of EVMs Considered Radio Frequency Products in Japan EVMs entering Japan are NOT certified by TI as conforming to Technical Regulations of Radio Law of ...

Страница 25: ...esponsible for compliance with all legal regulatory and safety related requirements concerning its products and any use of TI components in its applications notwithstanding any applications related information or support that may be provided by TI Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards which anticipate dangerous consequences of failur...

Страница 26: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information Texas Instruments UCD3138A64CEVM 660 ...

Отзывы: