Downloading Firmware
13
SLWU086C – November 2013 – Revised January 2016
Copyright © 2013–2016, Texas Instruments Incorporated
TSW14J56 JESD204B High-Speed Data Capture and Pattern Generator
Card User's Guide
For information regarding the use of the TSW14J56EVM with a TI ADC or DAC JESD204B serial interface
EVM, consult the High-Speed Data Converter Pro GUI User's Guide
and the individual EVM
User’s Guide, available on
.
If the message appears as shown in
, verify that all jumpers are in the default position and all
power status LEDs are illuminated. If certain jumpers are not installed in the proper location, the USB 3.0
Controller will not boot from flash memory. If any power status LED is off, there may be a problem with a
power supply on the board, which can prevent the firmware from downloading. Unplug and re-install the
USB connector and try to connect to the board. If this fails, cycle the power switch to re-initialize the
power-up sequencer to try to correct this problem.
Figure 8. Download Firmware Error Message