5 Power-Up Procedure
Power-up with dedicated enable pin:
1. Apply 4.5 V–17 V to J5
2. Toggle J6 , J7, or J8 to enable VOUT1, VOUT2, and VOUT3, respectively
3. Apply loads to the output connectors
Six bucks power sequence schemes with the pre-defined power up and power down sequence, shown in
1. Connect J9 to GND or high
2. Connect J6 to High(or Low), J7 to High(or Low)
3. Apply 4.5 V–18 V to J5
4. Toggle J8 to enable VOUT1, VOUT2, and VOUT3 (power up sequence shown in
)
5. Apply loads to the output connectors
Table 5-1. Power Sequencing
Mode
EN1
EN2
EN3
Start Sequencing
Shutdown Sequencing
Low
High
High
Used to start/stop bucks in
sequence
buck1→buck2→buck3
Buck3→buck2→buck1
Low
Low
High
Buck2→buck1→buck3
Buck3→buck1→buck2
Low
High
Low
Buck2→buck3→buck1
Buck1→buck3→buck2
High
High
High
Buck1→buck3→buck2
Buck2→buck3→buck1
High
Low
High
Buck3→buck1→buck2
Buck2→buck1→buck3
High
High
Low
Buck3→buck2→buck1
Buck1→buck2→buck3
High/Low
Low
Low
Reserved
Reserved
Reserved
Power-Up Procedure
SLVUAK9A – DECEMBER 2015 – REVISED MAY 2021
TPS65265 Buck Converter Evaluation Module User's Guide
9
Copyright © 2021 Texas Instruments Incorporated