33.5.9 ECAP Interrupt Flag Register (ECFLG)
Figure 33-22. ECAP Interrupt Flag Register (ECFLG) [offset = 2Ch]
15
8
Reserved
R-0
7
6
5
4
3
2
1
0
CTR_CMP
CTR_PRD
CTROVF
CEVT4
CETV3
CEVT2
CETV1
INT
R-0
R-0
R-0
R-0
R-0
R-0
R-0
R-0
LEGEND: R = Read only; -
n
= value after reset
Table 33-10. ECAP Interrupt Flag Register (ECFLG) Field Descriptions
Bits
Field
Value
Description
15-8
Reserved
0
Reserved
7
CTR_CMP
Compare Equal Compare Status Flag. This flag is active only in APWM mode.
0
Indicates no event occurred.
1
Indicates the counter (TSCTR) reached the compare register value (ACMP).
6
CTR_PRD
Counter Equal Period Status Flag. This flag is only active in APWM mode.
0
Indicates no event occurred.
1
Indicates the counter (TSCTR) reached the period register value (APRD) and was reset.
5
CTROVF
Counter Overflow Status Flag. This flag is active in CAP and APWM mode.
0
Indicates no event occurred.
1
Indicates the counter (TSCTR) has made the transition from FFFF FFFFh to 0000 0000h.
4
CEVT4
Capture Event 4 Status Flag This flag is only active in CAP mode.
0
Indicates no event occurred.
1
Indicates the fourth event occurred at ECAPx pin.
3
CEVT3
Capture Event 3 Status Flag. This flag is active only in CAP mode.
0
Indicates no event occurred.
1
Indicates the third event occurred at ECAPx pin.
2
CEVT2
Capture Event 2 Status Flag. This flag is only active in CAP mode.
0
Indicates no event occurred.
1
Indicates the second event occurred at ECAPx pin.
1
CEVT1
Capture Event 1 Status Flag. This flag is only active in CAP mode.
0
Indicates no event occurred.
1
Indicates the first event occurred at ECAPx pin.
0
INT
Global Interrupt Status Flag.
0
Indicates no interrupt generated.
1
Indicates that an interrupt was generated.