![Texas Instruments TMS320x2823x Скачать руководство пользователя страница 89](http://html1.mh-extra.com/html/texas-instruments/tms320x2823x/tms320x2823x_reference-manual_1095205089.webp)
www.ti.com
Applications to Power Topologies
Example 14. Code Snippet for Configuration in
//=====================================================================
// Config
//=====================================================================
// Initialization Time
//========================
// EPWM Module 1 config
EPwm1Regs.TBPRD = 1200;
// Period = 1201 TBCLK counts
EPwm1Regs.CMPA = 600;
// Set 50% fixed duty for EPWM1A
EPwm1Regs.TBPHS.half.TBPHS = 0;
// Set Phase register to zero
EPwm1Regs.TBCTL.bit.CTRMODE = TB_COUNT_UP;
// Asymmetrical mode
EPwm1Regs.TBCTL.bit.PHSEN = TB_DISABLE;
// Master module
EPwm1Regs.TBCTL.bit.PRDLD = TB_SHADOW;
EPwm1Regs.TBCTL.bit.SYNCOSEL = TB_CTR_ZERO;
// Sync down-stream module
EPwm1Regs.CMPCTL.bit.SHDWAMODE = CC_SHADOW;
EPwm1Regs.CMPCTL.bit.SHDWBMODE = CC_SHADOW;
EPwm1Regs.CMPCTL.bit.LOADAMODE = CC_CTR_ZERO;
// load on CTR=Zero
EPwm1Regs.CMPCTL.bit.LOADBMODE = CC_CTR_ZERO;
// load on CTR=Zero
EPwm1Regs.AQCTLA.bit.ZRO = AQ_SET;
// set actions for EPWM1A
EPwm1Regs.AQCTLA.bit.CAU = AQ_CLEAR;
EPwm1Regs.DBCTL.bit.OUT_MODE = DB_FULL_ENABLE;
// enable Dead-band module
EPwm1Regs.DBCTL.bit.POLSEL = DB_ACTV_HIC;
// Active Hi complementary
EPwm1Regs.DBFED = 50;
// FED = 50 TBCLKs initially
EPwm1Regs.DBRED = 70;
// RED = 70 TBCLKs initially
// EPWM Module 2 config
EPwm2Regs.TBPRD = 1200;
// Period = 1201 TBCLK counts
EPwm2Regs.CMPA.half.CMPA = 600;
// Set 50% fixed duty EPWM2A
EPwm2Regs.TBPHS.half.TBPHS = 0;
// Set Phase register to zero initially
EPwm2Regs.TBCTL.bit.CTRMODE = TB_COUNT_UP;
// Asymmetrical mode
EPwm2Regs.TBCTL.bit.PHSEN = TB_ENABLE;
// Slave module
EPwm2Regs.TBCTL.bit.PRDLD = TB_SHADOW;
EPwm2Regs.TBCTL.bit.SYNCOSEL = TB_SYNC_IN;
// sync flow-through
EPwm2Regs.CMPCTL.bit.SHDWAMODE = CC_SHADOW;
EPwm2Regs.CMPCTL.bit.SHDWBMODE = CC_SHADOW;
EPwm2Regs.CMPCTL.bit.LOADAMODE = CC_CTR_ZERO;
// load on CTR=Zero
EPwm2Regs.CMPCTL.bit.LOADBMODE = CC_CTR_ZERO;
// load on CTR=Zero
EPwm2Regs.AQCTLA.bit.ZRO = AQ_SET;
// set actions for EPWM2A
EPwm2Regs.AQCTLA.bit.CAU = AQ_CLEAR;
EPwm2Regs.DBCTL.bit.OUT_MODE = DB_FULL_ENABLE;
// enable Dead-band module
EPwm2Regs.DBCTL.bit.POLSEL = DB_ACTV_HIC;
// Active Hi complementary
EPwm2Regs.DBFED = 30;
// FED = 30 TBCLKs initially
EPwm2Regs.DBRED = 40;
// RED = 40 TBCLKs initially
// Run Time (Note: Example execution of one run-time instant)
//============================================================
EPwm2Regs.TBPHS = 1200-300;
// Set Phase reg to 300/1200 * 360 = 90 deg
EPwm1Regs.DBFED = FED1_NewValue;
// Update ZVS transition interval
EPwm1Regs.DBRED = RED1_NewValue;
// Update ZVS transition interval
EPwm2Regs.DBFED = FED2_NewValue;
// Update ZVS transition interval
EPwm2Regs.DBRED = RED2_NewValue;
// Update ZVS transition interval
EPwm1Regs.CMPB = 200;
// adjust point-in-time for ADCSOC trigger
89
SPRUG04A – October 2008 – Revised July 2009
TMS320x2833x, 2823x Enhanced Pulse Width Modulator (ePWM) Module
© 2008–2009, Texas Instruments Incorporated