Registers
Table 45. Event-Trigger Prescale Register (ETPS) Field Descriptions (continued)
Bits
Name
Description
1-0
INTPRD
ePWM Interrupt (EPWMx_INT) Period Select
These bits determine how many selected ETSEL[INTSEL] events need to occur before an
interrupt is generated. To be generated, the interrupt must be enabled (ETSEL[INT] = 1). If
the interrupt status flag is set from a previous interrupt (ETFLG[INT] = 1) then no interrupt will
be generated until the flag is cleared via the ETCLR[INT] bit. This allows for one interrupt to
be pending while another is still being serviced. Once the interrupt is generated, the
ETPS[INTCNT] bits will automatically be cleared.
Writing a INTPRD value that is the same as the current counter value will trigger an interrupt
if it is enabled and the status flag is clear.
Writing a INTPRD value that is less than the current counter value will result in an undefined
state.
If a counter event occurs at the same instant as a new zero or non-zero INTPRD value is
written, the counter is incremented.
00
Disable the interrupt event counter. No interrupt will be generated and ETFRC[INT] is
ignored.
01
Generate an interrupt on the first event INTCNT = 01 (first event)
10
Generate interrupt on ETPS[INTCNT] = 1,0 (second event)
11
Generate interrupt on ETPS[INTCNT] = 1,1 (third event)
Figure 88. Event-Trigger Flag Register (ETFLG)
15
8
Reserved
R-0
7
4
3
2
1
0
Reserved
SOCB
SOCA
Reserved
INT
R-0
R-0
R-0
R-0
R-0
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset
Table 46. Event-Trigger Flag Register (ETFLG) Field Descriptions
Bits
Name
Value
Description
15-4
Reserved
Reserved
3
SOCB
Latched ePWM ADC Start-of-Conversion B (EPWMxSOCB) Status Flag
0
Indicates no EPWMxSOCB event occurred
1
Indicates that a start of conversion pulse was generated on EPWMxSOCB. The
EPWMxSOCB output will continue to be generated even if the flag bit is set.
2
SOCA
Latched ePWM ADC Start-of-Conversion A (EPWMxSOCA) Status Flag
Unlike the ETFLG[INT] flag, the EPWMxSOCA output will continue to pulse even if the flag bit
is set.
0
Indicates no event occurred
1
Indicates that a start of conversion pulse was generated on EPWMxSOCA. The
EPWMxSOCA output will continue to be generated even if the flag bit is set.
1
Reserved
Reserved
0
INT
Latched ePWM Interrupt (EPWMx_INT) Status Flag
0
Indicates no event occurred
1
Indicates that an ePWMx interrupt (EWPMx_INT) was generated. No further interrupts will be
generated until the flag bit is cleared. Up to one interrupt can be pending while the
ETFLG[INT] bit is still set. If an interrupt is pending, it will not be generated until after the
ETFLG[INT] bit is cleared. Refer to
111
SPRUG04A – October 2008 – Revised July 2009
TMS320x2833x, 2823x Enhanced Pulse Width Modulator (ePWM) Module
© 2008–2009, Texas Instruments Incorporated