3.2.7 MDIO Module
The MDIO module is used to manage up to 32 physical layer (PHY) devices connected to the Ethernet
Media Access Controller (EMAC). The device supports a single PHY being connected to the EMAC at any
given time. The MDIO module is designed to allow almost transparent operation of the MDIO interface
with little maintenance from the CPU.
The MDIO module continuously polls 32 MDIO addresses in order to enumerate all PHY devices in the
system. Once a PHY device has been detected, the MDIO module reads the MDIO PHY link status
register (LINK) to monitor the PHY link state. Link change events are stored in the MDIO module, which
can interrupt the CPU. This storing of the events allows the CPU to poll the link status of the PHY device
without continuously performing MDIO module accesses. However, when the CPU must access the MDIO
module for configuration and negotiation, the MDIO module performs the MDIO read or write operation
independent of the CPU. This independent operation allows the processor to poll for completion or
interrupt the CPU once the operation has completed.
3.2.7.1
MDIO Module Components
The MDIO module (
) interfaces to the PHY components through two MDIO pins (MDCLK and
MDIO), and to the CPU through the EMAC control module and the configuration bus. The MDIO module
consists of the following logical components:
•
MDIO clock generator
•
Global PHY detection and link state monitoring
•
Active PHY monitoring
•
PHY register user access
Figure 3-9. MDIO Module Block Diagram
3.2.7.1.1 MDIO Clock Generator
The MDIO clock generator controls the MDIO clock based on a divide-down of the peripheral clock
(SYSCLK5) in the EMAC control module. The MDIO clock is specified to run up to 2.5 MHz, although
typical operation would be 1.0 MHz. Since the peripheral clock frequency is variable (SYSCLK5), the
application software or driver controls the divide-down amount.
3.2.7.1.2 Global PHY Detection and Link State Monitoring
The MDIO module continuously polls all 32 MDIO addresses in order to enumerate the PHY devices in the
system. The module tracks whether or not a PHY on a particular address has responded, and whether or
not the PHY currently has a link. Using this information allows the software application to quickly
determine which MDIO address the PHY is using.
428
EMAC/MDIO Module
SPRUGX9 – 15 April 2011
© 2011, Texas Instruments Incorporated
Содержание TMS320C6A816 Series
Страница 2: ...Preliminary 2 SPRUGX9 15 April 2011 Submit Documentation Feedback 2011 Texas Instruments Incorporated...
Страница 92: ...92 Read This First SPRUGX9 15 April 2011 Submit Documentation Feedback 2011 Texas Instruments Incorporated...
Страница 1122: ...1122 Multichannel Audio Serial Port McASP SPRUGX9 15 April 2011 Submit Documentation Feedback 2011 Texas Instruments Incorporated...
Страница 1562: ...1562 Real Time Clock RTC SPRUGX9 15 April 2011 Submit Documentation Feedback 2011 Texas Instruments Incorporated...
Страница 1658: ...1658 Timers SPRUGX9 15 April 2011 Submit Documentation Feedback 2011 Texas Instruments Incorporated...
Страница 1750: ...1750 UART IrDA CIR Module SPRUGX9 15 April 2011 Submit Documentation Feedback 2011 Texas Instruments Incorporated...
Страница 1984: ...1984 Universal Serial Bus USB SPRUGX9 15 April 2011 Submit Documentation Feedback 2011 Texas Instruments Incorporated...