3.2.2.5 Time-base Counter Modes and Timing Waveforms
The time-base counter operates in one of four modes:
• Up-count mode which is asymmetrical
• Down-count mode which is asymmetrical
• Up-down-count which is symmetrical
• Frozen where the time-base counter is held constant at the current value
To illustrate the operation of the first three modes, the following timing diagrams show when events are
generated and how the time-base responds to an EPWMxSYNCI signal.
0000
EPWMxSYNCI
TBCTR[15:0]
CTR_dir
CTR = zero
CNT_max
CTR = PRD
0xFFFF
TBPHS
(value)
TBPRD
(value)
Figure 3-8. Time-Base Up-Count Mode Waveforms
Enhanced Pulse Width Modulator (ePWM) Module
SPRUH18I – JANUARY 2011 – REVISED JUNE 2022
TMS320x2806x Microcontrollers
257
Copyright © 2022 Texas Instruments Incorporated