![Texas Instruments MCT8317 Скачать руководство пользователя страница 7](http://html.mh-extra.com/html/texas-instruments/mct8317/mct8317_user-manual_1094648007.webp)
Figure 4-4. MSP430FR2355 MCU and User Interface on MCT8317EVM
4.4 LED Lights
The MCT8317EVM has 7 status LEDs implemented that provide the status of power supplies and functionalities
of the evaluation module. By default, the VM LED and 3.3 V Buck LEDs will light up when the board is powered
and the program has been flashed onto the microcontroller.
shows LED descriptions including those
that are on during power up in bold and
shows the locations of the LEDs.
Table 4-1. Description of MCT8317EVM LEDs (default in bold after powerup)
Designator
Name
Color
Description
D1
AVDD
GREEN
Lights up when AVDD is turned ON.
D2
nFAULT
Red
Lights up when fault condition has occurred on MCT8317
D3
ALARM
Red
Lights up when alarm condition has occurred on MCT8317
D4
VM
Green
Lights up when voltage is applied on VM.
D6
MSP_LED1
Red
Used for UART or debugging
D7
MSP_LED2
Red
Used for UART or debugging
Hardware and Software Overview
MCT8317EVM Evaluation Module
7
Copyright © 2022 Texas Instruments Incorporated