![Texas Instruments DLP DLPC7540 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/texas-instruments/dlp-dlpc7540/dlp-dlpc7540_user-manual_1095630009.webp)
Figure 2-2. ON/OFF Switches
Once the power supply has been connected to the DLPC7540EVM, the switches SW5 and SW1 in that order
can be flipped to the
on
position. You can then plug in the USB cable to J2 of the board to prepare for
programming the board. Verify that D5, D6, D7 and D15 LEDs are on.
2.4 Programming the DLPC7540EVM and Displaying a SPLASH Image
Follow these steps in order to download and configure the DLPDLC-GUI for DLPC7540 operation:
1. Download the DLPDLC-GUI and the Firmware SW package that includes the Firmware binary (.img) files for
DLP471TE and DLP650TE.
2. Install and open the DLPDLC-GUI
3. Setting up Communication Preferences:
a. DLPDLC-GUI supports USB and I2C communication. To change these settings in GUI, please go to
Debug screen and select Connection tab.
b. For USB, please select the USB interface and click Connect
. Note: USB is the preferred
interface to download the firmware flash image to the EVM as it is much faster than I2C and won't
require any additional hardware.
Quick Start
DLPU109 – MAY 2021
DLP® Display DLPC7540 4K UHD EVM
9