Cell Voltage Monitor Tab (ADC Config)
12
SLUUBQ2C – July 2017 – Revised April 2019
Copyright © 2017–2019, Texas Instruments Incorporated
Getting Started with the BQ79606A-Q1 GUI
Figure 15. ADC Config for Continuous Readings
2. After completing step 1, the ADC values will be stored in their respective registers and are ready to be
read.
a. Click “read” to update cell values.
b. Values will be read in as a voltage, or alternatively as a two bye Hex value
c. VCELLX_F contains cell values after the ADC output filter
d. VCELLX contains corrected cell values before the ADC output filter
e. To continue updating cell voltages, click “Read” again to update cell voltages as seen in
.
f.
Repeat step e as needed to update cell voltage registers