Texas Instruments BQ76PL536EVM-3 Скачать руководство пользователя страница 9

www.ti.com

Evaluation Software Details

5.1.1

Volatile RAM Configuration Registers –

The lower half of this area displays the volatile configuration registers shown as bit fields, see the
bq76PL536A or bq76PL536A-Q1 data sheet for details on programming these registers. These registers
display green for logic 0 and orange for logic 1. The two states may be toggled between by left-clicking on
the bit

The STATUS, COV_FAULT, and CUV_FAULT bits are either white (logic 0) or red (logic 1) for asserted.
In most cases, the asserted state indicates an error condition sensed by the bq76PL536A.

To clear a fault, first remove the physical condition causing the fault, then click on the ALERT or FAULT
bit to reset the state of the bit. This writes a 1 to the bit, followed by a 0, which is the device’s method for
clearing the asserted bit state back to logic 0.

5.1.2

Group-3 Protected Registers –

The device is provided with many configuration options set by bits contained in a special set of registers
protected against accidental writing. These RAM registers are initialized from OTP (One-Time
Programmable) EPROM cells. The device is shipped with these EPROM locations un-programmed
(blank). The Windows GUI interface hides the un-programmed nature of the device by setting defaults in
the registers cells when the Evaluation software starts (this can be defeated by setting the TOOLS |
OPTIONS defaults). The last settings are also automatically saved by the GUI and restored upon next
use. These features are provided for ease of use and are implemented solely in the GUI. Users are
responsible for programming OTP bits in parts correctly during manufacturing for correct operation in-
circuit.

Some Group-3 registers are shown as registers at the bottom of the left side of the screen, the others in
the top right section of the screen as listboxes and registers

5.1.3

Quick Access

The Quick Access register(s) provide R/W access to any location in the part. They are named arbitrarily in
the GUI ‘X’, ‘Y’, and ‘Z’ – there are no XYZ registers in the part. Some registers, such as the MASTER
register require multi-byte writes to “unlock” the target register for writing. To accomplish this, program the
X register address/data with the first unlock key, the Y register with the second unlock key, and finally the
Z register with the target address and data. Then use the “write all” button to send all three address/data
bytes in the correct order and timing to accomplish the multi-byte write. (This is done automatically when
using the

Protected Registers

window.)

5.1.4

LED Status Indicators

At the top right of the user interface screen are 8 status indicator "LED's". These provide a quick view of
the status of the devices, and the interface, cable connections, etc. Green normally indicates a logic 0
condition, and red a logic one condition. Gray indicates undefined.

ALERT

A condition has been sensed that is causing the ALERT hardware pin to be asserted. This
is also indicated by the ALERT bit being set (red) in the [DEVICE] STATUS register. The
source of the ALERT condition is indicated in the ALERT register just below the STATUS
register.

FAULT

Similar to the ALERT indicator, this LED indicates the FAULT bit, and FAULT hardware
pin are asserted. The source is indicated in the FAULT register just below the ALERT
register.

9

SLUU437D – October 2010 – Revised July 2015

bq76PL536A and bq76PL536A-Q1 EVM Quick Start Guide

Submit Documentation Feedback

Copyright © 2010–2015, Texas Instruments Incorporated

Содержание BQ76PL536EVM-3

Страница 1: ...nstalled before attaching the adapter for the first time The Aardvark driver should be installed prior to installing the TI supplied bq76PL536A and bq76PL536A Q1 Evaluation software 1 Download the USB...

Страница 2: ...l inputs and are supplied to use the EVM with power supplies in place of cells see Use with 12 26 VDC Power Supply Connect cells to the supplied mating connectors with screw terminals BEFORE plugging...

Страница 3: ...the mating connector the pin that will connect to the bottom most pin of the mating connector The positive connection is made to pin 7 the top most on the connector It is not necessary to connect to...

Страница 4: ...Installed and outputs must remain isolated from earth ground EVM Assembly and Configuration www ti com Figure 1 Correct Connection of Three 20 V Power Supplies to bq76PL536EVM 3 Figure 2 Alternate Con...

Страница 5: ...er 18K does not supply sufficient current to ICs Base IC must be powered www ti com EVM Assembly and Configuration Figure 3 Incorrect Connections Base IC Not Powered Figure 4 Incorrect Connections Ins...

Страница 6: ...ces may be powered in order from negative to positive in lieu of powering all three devices Due to poor termination of the unpowered devices in this configuration detailed testing or critical hardware...

Страница 7: ...the EVM as part of a stack where lethal voltages may be present The galvanic isolation provided by the ISO COMMS section does not eliminate the need for safe handling procedures proper High Voltage eq...

Страница 8: ...breviated to WinGUI VBRICK The voltage measured by the bq76PL536A between the BATx and VSS pins VCELLn The voltage measured between the pair of pins VCn VCn 1 that is VCELL2 VC2 VC1 ADDR Displays the...

Страница 9: ...ufacturing for correct operation in circuit Some Group 3 registers are shown as registers at the bottom of the left side of the screen the others in the top right section of the screen as listboxes an...

Страница 10: ...ff to access them RATE This list box allows choosing a polling rate between 100ms and 60s The LED illuminates green each time the GUI polls the device stack Useful as a heartbeat indicator when pollin...

Страница 11: ...alues and registers to update The user hould see all cell voltages displayed along with registers showing FAULT and ALERT status DEVICE STATUS etc 5 3 Menus and Commands 5 3 1 File Menu This menu prov...

Страница 12: ...f alarms FAULTS and ALERTS at startup Programmers wishing to check their code will want to disable most of these startup niceties during final code checkout See Packing List for details of the startup...

Страница 13: ...etails Figure 7 SPI Monitor Showing Communications Error 13 SLUU437D October 2010 Revised July 2015 bq76PL536A and bq76PL536A Q1 EVM Quick Start Guide Submit Documentation Feedback Copyright 2010 2015...

Страница 14: ...t disabling COV FAULTs DISABLE CUV sets the CONFIG_CUV DISABLE bit disabling CUV ALERTs CLEAR LATCHED BITS clears all FAULT and ALERT bits latched in the FAULT and ALERT registers which may have other...

Страница 15: ...tures The data captured to the plot are not automatically captured in a log file The data are available for use or saving in a variety of formats while the program is running The plotted data are lost...

Страница 16: ...t time scale EXPAND X Y This control allows zooming in or out on the displayed scale Choose this button then click and hold the left mouse button to operate Each data set VCn voltages VBRICK temperatu...

Страница 17: ...acle 7 20 ea 2 pin jumpers 025 post 0 10 cntr 8 1 ea CD ROM containing software and documentation Revision History Changes from B Revision May 2011 to D Revision Page Revision C was deprecated 1 Chang...

Страница 18: ...product This notice contains important safety information about temperatures and voltages For additional information on TI s environmental and or safety programs please contact the TI application engi...

Страница 19: ...ing the warranty period to the address designated by TI and that are determined by TI not to conform to such warranty If TI elects to repair or replace such EVM TI shall have a reasonable time to repa...

Страница 20: ...transmitter has been approved by Industry Canada to operate with the antenna types listed in the user guide with the maximum permissible gain and required antenna impedance for each antenna type indic...

Страница 21: ...ified allowable ranges some circuit components may have elevated case temperatures These components include but are not limited to linear regulators switching transistors pass transistors current sens...

Страница 22: ...REMOVAL OR REINSTALLATION ANCILLARY COSTS TO THE PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES RETESTING OUTSIDE COMPUTER TIME LABOR COSTS LOSS OF GOODWILL LOSS OF PROFITS LOSS OF SAVINGS LOSS OF USE L...

Страница 23: ...sponsible for compliance with all legal regulatory and safety related requirements concerning its products and any use of TI components in its applications notwithstanding any applications related inf...

Страница 24: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information Texas Instruments BQ76PL536EVM 3...

Отзывы: