Texas Instruments BQ76PL536EVM-3 Скачать руководство пользователя страница 18

Evaluation Board/Kit Important Notice

Texas Instruments (TI) provides the enclosed product(s) under the following conditions:

This evaluation board/kit is intended for use for

ENGINEERING DEVELOPMENT, DEMONSTRATION, OR EVALUATION PURPOSES

ONLY

and is not considered by TI to be a finished end-product fit for general consumer use. Persons handling the product(s) must have

electronics training and observe good engineering practice standards. As such, the goods being provided are not intended to be complete
in terms of required design-, marketing-, and/or manufacturing-related protective considerations, including product safety and environmental
measures typically found in end products that incorporate such semiconductor components or circuit boards. This evaluation board/kit does
not fall within the scope of the European Union directives regarding electromagnetic compatibility, restricted substances (RoHS), recycling
(WEEE), FCC, CE or UL, and therefore may not meet the technical requirements of these directives or other related directives.

Should this evaluation board/kit not meet the specifications indicated in the User’s Guide, the board/kit may be returned within 30 days from
the date of delivery for a full refund. THE FOREGOING WARRANTY IS THE EXCLUSIVE WARRANTY MADE BY SELLER TO BUYER
AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED, IMPLIED, OR STATUTORY, INCLUDING ANY WARRANTY OF
MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE.

The user assumes all responsibility and liability for proper and safe handling of the goods. Further, the user indemnifies TI from all claims
arising from the handling or use of the goods. Due to the open construction of the product, it is the user’s responsibility to take any and all
appropriate precautions with regard to electrostatic discharge.

EXCEPT TO THE EXTENT OF THE INDEMNITY SET FORTH ABOVE, NEITHER PARTY SHALL BE LIABLE TO THE OTHER FOR ANY
INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES.

TI currently deals with a variety of customers for products, and therefore our arrangement with the user

is not exclusive.

TI assumes

no liability for applications assistance, customer product design, software performance, or infringement of patents or

services described herein.

Please read the User’s Guide and, specifically, the Warnings and Restrictions notice in the User’s Guide prior to handling the product. This
notice contains important safety information about temperatures and voltages. For additional information on TI’s environmental and/or
safety programs, please contact the TI application engineer or visit

www.ti.com/esh

.

No license is granted under any patent right or other intellectual property right of TI covering or relating to any machine, process, or
combination in which such TI products or services might be or are used.

FCC Warning

This evaluation board/kit is intended for use for

ENGINEERING DEVELOPMENT, DEMONSTRATION, OR EVALUATION PURPOSES

ONLY

and is not considered by TI to be a finished end-product fit for general consumer use. It generates, uses, and can radiate radio

frequency energy and has not been tested for compliance with the limits of computing devices pursuant to part 15 of FCC rules, which are
designed to provide reasonable protection against radio frequency interference. Operation of this equipment in other environments may
cause interference with radio communications, in which case the user at his own expense will be required to take whatever measures may
be required to correct this interference.

EVM Warnings and Restrictions

It is important to operate this EVM within the input voltage range of 7V to 36V and the output voltage range of 7V to 35V .

Exceeding the specified input range may cause unexpected operation and/or irreversible damage to the EVM. If there are questions
concerning the input range, please contact a TI field representative prior to connecting the input power.

Applying loads outside of the specified output range may result in unintended operation and/or possible permanent damage to the EVM.
Please consult the EVM User's Guide prior to connecting any load to the EVM output. If there is uncertainty as to the load specification,
please contact a TI field representative.

During normal operation, some circuit components may have case temperatures greater than 85°C. The EVM is designed to operate
properly with certain components above 85°C as long as the input and output ranges are maintained. These components include but are
not limited to linear regulators, switching transistors, pass transistors, and current sense resistors. These types of devices can be identified
using the EVM schematic located in the EVM User's Guide. When placing measurement probes near these devices during operation,
please be aware that these devices may be very warm to the touch.

Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265

Copyright © 2015, Texas Instruments Incorporated

Содержание BQ76PL536EVM-3

Страница 1: ...nstalled before attaching the adapter for the first time The Aardvark driver should be installed prior to installing the TI supplied bq76PL536A and bq76PL536A Q1 Evaluation software 1 Download the USB...

Страница 2: ...l inputs and are supplied to use the EVM with power supplies in place of cells see Use with 12 26 VDC Power Supply Connect cells to the supplied mating connectors with screw terminals BEFORE plugging...

Страница 3: ...the mating connector the pin that will connect to the bottom most pin of the mating connector The positive connection is made to pin 7 the top most on the connector It is not necessary to connect to...

Страница 4: ...Installed and outputs must remain isolated from earth ground EVM Assembly and Configuration www ti com Figure 1 Correct Connection of Three 20 V Power Supplies to bq76PL536EVM 3 Figure 2 Alternate Con...

Страница 5: ...er 18K does not supply sufficient current to ICs Base IC must be powered www ti com EVM Assembly and Configuration Figure 3 Incorrect Connections Base IC Not Powered Figure 4 Incorrect Connections Ins...

Страница 6: ...ces may be powered in order from negative to positive in lieu of powering all three devices Due to poor termination of the unpowered devices in this configuration detailed testing or critical hardware...

Страница 7: ...the EVM as part of a stack where lethal voltages may be present The galvanic isolation provided by the ISO COMMS section does not eliminate the need for safe handling procedures proper High Voltage eq...

Страница 8: ...breviated to WinGUI VBRICK The voltage measured by the bq76PL536A between the BATx and VSS pins VCELLn The voltage measured between the pair of pins VCn VCn 1 that is VCELL2 VC2 VC1 ADDR Displays the...

Страница 9: ...ufacturing for correct operation in circuit Some Group 3 registers are shown as registers at the bottom of the left side of the screen the others in the top right section of the screen as listboxes an...

Страница 10: ...ff to access them RATE This list box allows choosing a polling rate between 100ms and 60s The LED illuminates green each time the GUI polls the device stack Useful as a heartbeat indicator when pollin...

Страница 11: ...alues and registers to update The user hould see all cell voltages displayed along with registers showing FAULT and ALERT status DEVICE STATUS etc 5 3 Menus and Commands 5 3 1 File Menu This menu prov...

Страница 12: ...f alarms FAULTS and ALERTS at startup Programmers wishing to check their code will want to disable most of these startup niceties during final code checkout See Packing List for details of the startup...

Страница 13: ...etails Figure 7 SPI Monitor Showing Communications Error 13 SLUU437D October 2010 Revised July 2015 bq76PL536A and bq76PL536A Q1 EVM Quick Start Guide Submit Documentation Feedback Copyright 2010 2015...

Страница 14: ...t disabling COV FAULTs DISABLE CUV sets the CONFIG_CUV DISABLE bit disabling CUV ALERTs CLEAR LATCHED BITS clears all FAULT and ALERT bits latched in the FAULT and ALERT registers which may have other...

Страница 15: ...tures The data captured to the plot are not automatically captured in a log file The data are available for use or saving in a variety of formats while the program is running The plotted data are lost...

Страница 16: ...t time scale EXPAND X Y This control allows zooming in or out on the displayed scale Choose this button then click and hold the left mouse button to operate Each data set VCn voltages VBRICK temperatu...

Страница 17: ...acle 7 20 ea 2 pin jumpers 025 post 0 10 cntr 8 1 ea CD ROM containing software and documentation Revision History Changes from B Revision May 2011 to D Revision Page Revision C was deprecated 1 Chang...

Страница 18: ...product This notice contains important safety information about temperatures and voltages For additional information on TI s environmental and or safety programs please contact the TI application engi...

Страница 19: ...ing the warranty period to the address designated by TI and that are determined by TI not to conform to such warranty If TI elects to repair or replace such EVM TI shall have a reasonable time to repa...

Страница 20: ...transmitter has been approved by Industry Canada to operate with the antenna types listed in the user guide with the maximum permissible gain and required antenna impedance for each antenna type indic...

Страница 21: ...ified allowable ranges some circuit components may have elevated case temperatures These components include but are not limited to linear regulators switching transistors pass transistors current sens...

Страница 22: ...REMOVAL OR REINSTALLATION ANCILLARY COSTS TO THE PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES RETESTING OUTSIDE COMPUTER TIME LABOR COSTS LOSS OF GOODWILL LOSS OF PROFITS LOSS OF SAVINGS LOSS OF USE L...

Страница 23: ...sponsible for compliance with all legal regulatory and safety related requirements concerning its products and any use of TI components in its applications notwithstanding any applications related inf...

Страница 24: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information Texas Instruments BQ76PL536EVM 3...

Отзывы: