background image

FCC Interference Statement for Class B EVM devices

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of
the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance
with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more
of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

Consult the dealer or an experienced radio/TV technician for help.

3.2

Canada

3.2.1

For EVMs issued with an Industry Canada Certificate of Conformance to RSS-210

Concerning EVMs Including Radio Transmitters:

This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions:
(1) this device may not cause interference, and (2) this device must accept any interference, including interference that may
cause undesired operation of the device.

Concernant les EVMs avec appareils radio:

Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation
est autorisée aux deux conditions suivantes: (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit
accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.

Concerning EVMs Including Detachable Antennas:

Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser)
gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type
and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for
successful communication. This radio transmitter has been approved by Industry Canada to operate with the antenna types
listed in the user guide with the maximum permissible gain and required antenna impedance for each antenna type indicated.
Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited
for use with this device.

Concernant les EVMs avec antennes détachables

Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d'un type et
d'un gain maximal (ou inférieur) approuvé pour l'émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage
radioélectrique à l'intention des autres utilisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope
rayonnée équivalente (p.i.r.e.) ne dépasse pas l'intensité nécessaire à l'établissement d'une communication satisfaisante. Le
présent émetteur radio a été approuvé par Industrie Canada pour fonctionner avec les types d'antenne énumérés dans le
manuel d’usage et ayant un gain admissible maximal et l'impédance requise pour chaque type d'antenne. Les types d'antenne
non inclus dans cette liste, ou dont le gain est supérieur au gain maximal indiqué, sont strictement interdits pour l'exploitation de
l'émetteur

3.3

Japan

3.3.1

Notice for EVMs delivered in Japan:

Please see

http://www.tij.co.jp/lsds/ti_ja/general/eStore/notice_01.page

日本国内に

輸入される評価用キット、ボードについては、次のところをご覧ください。

http://www.tij.co.jp/lsds/ti_ja/general/eStore/notice_01.page

3.3.2

Notice for Users of EVMs Considered “Radio Frequency Products” in Japan:

EVMs entering Japan are NOT certified by

TI as conforming to Technical Regulations of Radio Law of Japan.

If User uses EVMs in Japan, User is required by Radio Law of Japan to follow the instructions below with respect to EVMs:

1.

Use EVMs in a shielded room or any other test facility as defined in the notification #173 issued by Ministry of Internal
Affairs and Communications on March 28, 2006, based on Sub-section 1.1 of Article 6 of the Ministry’s Rule for
Enforcement of Radio Law of Japan,

2.

Use EVMs only after User obtains the license of Test Radio Station as provided in Radio Law of Japan with respect to
EVMs, or

3.

Use of EVMs only after User obtains the Technical Regulations Conformity Certification as provided in Radio Law of Japan
with respect to EVMs. Also, do not transfer EVMs, unless User gives the same notice above to the transferee. Please note
that if User does not follow the instructions above, User will be subject to penalties of Radio Law of Japan.

SPACER

SPACER

SPACER

SPACER

SPACER

Содержание bq34z100

Страница 1: ...tions Contents 1 Features 2 1 1 Kit Contents 2 1 2 Ordering Information 2 1 3 Documentation 2 1 4 bq34z100 Circuit Module Performance Specification Summary 2 2 bq34z100 Quick Start Guide 3 2 1 Items Needed for EVM Setup and Evaluation 3 2 2 Software Installation 3 2 3 EVM Connections 4 3 Battery Management Studio 6 3 1 Registers Screen 6 3 2 Setting Programmable bq34z100 Options 7 3 3 Calibration ...

Страница 2: ...V2400 Communications Interface Adapter 1 2 Ordering Information Table 1 Ordering Information EVM Part Number Chemistry Configuration Capacity Li Ion Li Polymer LiFePO4 PbA bq34z100EVM 3 V 48 V Any NiMH NiCd 1 3 Documentation See the device data sheet for bq34z100 G1 SLUSBZ5 on www ti com for information on device firmware and hardware 1 4 bq34z100 Circuit Module Performance Specification Summary T...

Страница 3: ...s Interface Adapter was not previously installed after the Battery Management Studio installation a TI USB driver installer pops up Click Yes for the agreement message and follow the instructions Two drivers are associated with the EV2300 and an additional file may be required for the EV2400 Follow the instructions to install both Do not reboot the computer even if asked to do so 3 Plug the Commun...

Страница 4: ...on To the serial communications port SCL SDA Attach the Communications Interface Adapter cable to the J7 terminal block and to an EV2300 or EV2400 adapter box Connect the PC USB cable to the EV2300 or EV2400 and the PC USB port see Figure 1 The charger and system load connection across BAT and PACK Attach the charger or load to the TB3 terminal block Connect the positive load wire to BAT and the g...

Страница 5: ...n EXT In all cases where one or more LED s are used place a jumper across the J1 header to provide power to the LED see Figure 1 Parameter setup The default data flash settings configure the device for 1 series Li Ion cell The user must update the data to set up the number of series cells to match the physical pack configuration see Cell Configuration in Section 3 2 This provides basic functionali...

Страница 6: ... Data begins to appear once the Refresh single time scan button is selected or it scans continuously if the Scan button is selected Figure 2 Registers Screen The continuous scanning period can be set via the Window Preferences SBS Scan Interval menu selection The Battery Management Studio program provides a logging function which logs the values selected by the Log check boxes located beside each ...

Страница 7: ...to select the mode of operation Refer to the Section 2 3 For packs where the stack voltage is less than 5 V Set the Number of Series Cells parameter field to the appropriate value Reset the gauge using the RESET button on the Commands panel Calibrate the stack voltage Reference the Calibration Screen section For packs where the stack voltage is less than 5 V Set the Number of Series Cells paramete...

Страница 8: ...system Deselect the Calibrate Voltage boxes after voltage calibration has completed 3 3 2 Temperature Calibration Enter the room temperature in the Applied Temperature field and select the Calibrate Temperature box and select the thermistor to be calibrated The temperature value must be entered in degrees Celsius Press the Calibrate Gas Gauge button to calibrate the temperature measurement system ...

Страница 9: ...emistry file contains parameters that the simulations use to model the cell and its operating profile It is critical to program a Chemistry ID that matches the cell into the device Some of these parameters can be viewed in the Data Flash section of the Battery Management Studio Press the Chemistry button to select the Chemistry window See Figure 5 Figure 5 Chemistry Screen The table can be sorted ...

Страница 10: ...to initialize the device by loading the default srec into the flash memory see Figure 6 Search for the srec file using the Browse button Press the Program button and wait for the download to complete Press the Execute FW button after the download has completed Select File Restart to initialize bqStudio to the new firmware 10 bq34z100EVM Wide Range Impedance Track Enabled Battery Fuel Gauge SLUU904...

Страница 11: ...s contains the program memory portion for the flash memory and the df fs contains the data flash portion of the flash memory see Figure 7 Select the directory location to export the files Enter the file name for the files Select the files types to export Press the Create Image File button to export the memory and create the files 11 SLUU904A April 2012 Revised February 2015 bq34z100EVM Wide Range ...

Страница 12: ...the Read button Date returned 8C 3C which a byte swapped 0x3C8C 15500mV when converted to decimal Sending a MAC Gauging to enable IT via ManufacturerAccess With Impedance Track disabled send Gauging 0x0021 to ManufacturerAccess Start Register 0x00 Bytes to Write 21 00 Press the Write button The QEN flag should set in the Control Status register to indicate that Impedance Track is enabled 12 bq34z1...

Страница 13: ...to Write 08 00 Press the Write button Start Register 0x00 Number of Bytes to Read 2 Press the Read button Date returned 07 01 which a byte swapped That is 0x0107 chem ID 107 13 SLUU904A April 2012 Revised February 2015 bq34z100EVM Wide Range Impedance Track Enabled Battery Fuel Gauge Solution Submit Documentation Feedback Copyright 2012 2015 Texas Instruments Incorporated ...

Страница 14: ...cations port HDQ GND Attach the Communications Interface Adapter cable to the J7 terminal block I2C Interface to the I2C port on the EV2300 Press the Convert From I2C to HDQ button Power cycle the voltage to the device Attach the Communications Interface Adapter cable to the J4 terminal block HDQ Interface to the HDQ port on the EV2300 Select File Restart to reload the bqStudio program WARNING The...

Страница 15: ... disabled by clicking the auto refresh field at the top of the panel see Figure 2 3 10 Commands Panel The Commands panel provides a quick and easy access to frequently used I2C and MAC commands They are mapped to buttons that can be pressed to execute the function The I2C transaction is logged in the Log Panel see Figure 2 15 SLUU904A April 2012 Revised February 2015 bq34z100EVM Wide Range Impedan...

Страница 16: ...P6 TP5 J5 U2 Circuit Module Physical Layouts www ti com 4 Circuit Module Physical Layouts This section contains the printed circuit board PCB layout assembly drawings and schematic for the bq34z100 circuit module 4 1 Board Layout This section shows the dimensions PCB layers Figure 10 through Figure 15 and assembly drawing for the bq34z100 module Figure 10 Top Silk Screen Figure 11 Top Assembly 16 ...

Страница 17: ...igure 12 Top Layer Figure 13 Internal Layer 1 17 SLUU904A April 2012 Revised February 2015 bq34z100EVM Wide Range Impedance Track Enabled Battery Fuel Gauge Solution Submit Documentation Feedback Copyright 2012 2015 Texas Instruments Incorporated ...

Страница 18: ...ure 14 Internal Layer 2 Figure 15 Bottom Layer 18 bq34z100EVM Wide Range Impedance Track Enabled Battery Fuel Gauge SLUU904A April 2012 Revised February 2015 Solution Submit Documentation Feedback Copyright 2012 2015 Texas Instruments Incorporated ...

Страница 19: ...C 3 YEL D9 QTLP610C 7 RED D10 QTLP610C 7 RED D11 QTLP610C 7 RED D12 QTLP610C 3 YEL R9 1 5K R10 1 5K R11 1 5K R12 1 5K D14 QTLP610C 3 YEL R18 1 5K D15 QTLP610C 4 GRN R20 1 5K R22 1 5K D17 QTLP610C 4 GRN R23 1 5K R24 1 5K C3 0 1uF C4 0 1uF D8 QTLP610C 4 GRN D3 QTLP610C 4 GRN D4 QTLP610C 4 GRN D5 QTLP610C 4 GRN Q6 2SK3019 1 2 3 4 5 6 7 8 9 10 J6 R25 200 1 2 3 4 5 6 J2 TP3 TP4 TP8 TP7 TP6 TP5 R15 1 5K...

Страница 20: ...R27 300 kΩ Resistor chip 0 1W 0 1 25 ppm C 0603 RG1608P 304 B T5 SSM 1 R2 100 kΩ Resistor chip 1 16W 1 0402 Std Std 2 R3 R41 27 kΩ Resistor chip 1 16 W 5 0402 Std Std 1 R21 220 kΩ Resistor chip 1 16W 5 0402 Std Std 1 R25 200 Ω Resistor chip 1 16W 5 0603 Std Any 1 R28 16 5 kΩ Resistor chip 0 1W 0 1 25 ppm C 0603 RG1608P 1652 B T5 SSM 2 R29 R31 10 kΩ Resistor chip 1 16W 5 0402 Std Std 1 R30 010 Ω Re...

Страница 21: ... and third column of the Ordering information 2 Added Documentation and subheadings to the first section 2 Changed or rearranged most of this User Guide with new text tables and graphics 3 Changed Schematic 19 Changed Bill of Materials 20 NOTE Page numbers for previous revisions may differ from page numbers in the current version 21 SLUU904A April 2012 Revised February 2015 Revision History Submit...

Страница 22: ...ring the warranty period to the address designated by TI and that are determined by TI not to conform to such warranty If TI elects to repair or replace such EVM TI shall have a reasonable time to repair such EVM or provide replacements Repaired EVMs shall be warranted for the remainder of the original warranty period Replaced EVMs shall be warranted for a new full ninety 90 day warranty period 3 ...

Страница 23: ...io transmitter has been approved by Industry Canada to operate with the antenna types listed in the user guide with the maximum permissible gain and required antenna impedance for each antenna type indicated Antenna types not included in this list having a gain greater than the maximum gain indicated for that type are strictly prohibited for use with this device Concernant les EVMs avec antennes d...

Страница 24: ... any load to the EVM output If there is uncertainty as to the load specification please contact a TI field representative During normal operation even with the inputs and outputs kept within the specified allowable ranges some circuit components may have elevated case temperatures These components include but are not limited to linear regulators switching transistors pass transistors current sense...

Страница 25: ...F REMOVAL OR REINSTALLATION ANCILLARY COSTS TO THE PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES RETESTING OUTSIDE COMPUTER TIME LABOR COSTS LOSS OF GOODWILL LOSS OF PROFITS LOSS OF SAVINGS LOSS OF USE LOSS OF DATA OR BUSINESS INTERRUPTION NO CLAIM SUIT OR ACTION SHALL BE BROUGHT AGAINST TI MORE THAN ONE YEAR AFTER THE RELATED CAUSE OF ACTION HAS OCCURRED 8 2 Specific Limitations IN NO EVENT SHALL T...

Страница 26: ...esponsible for compliance with all legal regulatory and safety related requirements concerning its products and any use of TI components in its applications notwithstanding any applications related information or support that may be provided by TI Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards which anticipate dangerous consequences of failur...

Страница 27: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information Texas Instruments BQ34Z100EVM ...

Отзывы: