Table 15-9. Short Circuit in Discharge 1 Delay
(Settings:AFE:AFE Protection Control [SCDDx2] = 0)
Setting
Time
Setting
Time
Setting
Time
Setting
Time
0x00
0 µs
0x04
244 µs
0x08
488 µs
0x0C
732 µs
0x01
61 µs
0x05
305 µs
0x09
549 µs
0x0D
793 µs
0x02
122 µs
0x06
366 µs
0x0A
610 µs
0x0E
854 µs
0x03
183 µs
0x07
427 µs
0x0B
671 µs
0x0F
915 µs
(1)
The data flash setting
Protection:AFE Thresholds:SCD1Threshold[7:4]
sets the delay time.
Table 15-10. Short Circuit in Discharge 1 Delay
(Settings:AFE:AFE Protection Control [SCDDx2] = 1)
Setting
Time
Setting
Time
Setting
Time
Setting
Time
0x00
0 µs
0x04
488 µs
0x08
976 µs
0x0C
1464 µs
0x01
122 µs
0x05
610 µs
0x09
1098 µs
0x0D
1586 µs
0x02
244 µs
0x06
732 µs
0x0A
1220 µs
0x0E
1708 µs
0x03
366 µs
0x07
854 µs
0x0B
1342 µs
0x0F
1830 µs
(1)
The data flash setting
Protection:AFE Thresholds:SCD1 Threshold[7:4]
sets the delay time.
Table 15-11. Short Circuit in Discharge 2 Delay
(Settings:AFE:AFE Protection Control [SCDDx2] = 0)
Setting
Time
Setting
Time
Setting
Time
Setting
Time
0x00
0 µs
0x04
122 µs
0x08
244 µs
0x0C
366 µs
0x01
31 µs
0x05
153 µs
0x09
275 µs
0x0D
396 µs
0x02
61 µs
0x06
183 µs
0x0A
305 µs
0x0E
427 µs
0x03
92 µs
0x07
214 µs
0x0B
335 µs
0x0F
458 µs
(1)
The data flash setting
Protection:AFE Thresholds:SCD2 Threshold[7:4]
sets the delay time.
Table 15-12. Short Circuit in Discharge 2 Delay
(Settings:AFE:AFE Protection Control [SCDDx2] = 1)
Setting
Time
Setting
Time
Setting
Time
Setting
Time
0x00
0 µs
0x04
244 µs
0x08
488 µs
0x0C
732 µs
0x01
62 µs
0x05
306 µs
0x09
550 µs
0x0D
792 µs
0x02
122 µs
0x06
366 µs
0x0A
610 µs
0x0E
854 µs
0x03
184 µs
0x07
428 µs
0x0B
670 µs
0x0F
916 µs
(1)
The data flash setting
Protection:AFE Thresholds:SCD2 Threshold[7:4]
sets the delay time.
AFE Threshold and Delay Settings
SLUUCO0 – APRIL 2022
BQ28Z610-R2
131
Copyright © 2022 Texas Instruments Incorporated
Содержание BQ28Z610-R2
Страница 1: ...BQ28Z610 R2 Technical Reference Manual Literature Number SLUUCO0 APRIL 2022 ...
Страница 2: ......