• If
FET Options[CHGFET]
= 1 and
GaugingStatus()[TC]
= 1, CHG FET turns off.
• If
Gauging Configuration[CSYNC]
= 1,
RemainingCapacity()
=
FullChargeCapacity()
.
• If
Gauging Configuration[RSOCL]
= 1,
RelativeStateOfCharge()
and
RemainingCapacity()
are held at 99%
until charge termination occurs. Only on entering charge termination is 100% displayed.
• If
Gauging Configuration[RSOCL]
= 0,
RelativeStateOfCharge()
and
RemainingCapacity()
are not held at
99% until charge termination occurs. Fractions of % greater than 99% are rounded up to display 100%.
Status
Condition
Action
Charging
GaugingStatus()[REST]
= 0 AND
GaugingStatus()
[DSG]
= 0
Charge Algorithm active
Valid Charge
Termination
All of the following conditions must occur for two
consecutive 40-s periods:
Charging (that is,
BatteryStatus[DSG]
= 0) AND
AverageCurrent()
<
Charge Term Taper Current
AND
Max (
CellVoltage2...1
) +
Charge Term Voltage
≥
ChargingVoltage()
/number of cells in series AND
The accumulated change in capacity > 0.25 mAh
ChargingStatus()[VCT]
= 1
ChargingStatus()[MCHG]
= 1
ChargingVoltage()
= Charging Algorithm
ChargingCurrent()
= Charging Algorithm
BatteryStatus()[FC]
= 1 and
GaugingStatus()[FC]
= 1 if
SOCFlagConfig A[FCSETVCT]
= 1
BatteryStatus()[TCA]
= 1 and
GaugingStatus()[TCA]
= 1 if
SOCFlagConfig B[TCSETVCT]
= 1
4.7 Charge and Discharge Alarms
The
[TC]
and
[FC]
bits in
GaugingStatus()
can be set at charge termination and based on RSOC or cell voltages.
If multiple set and clear conditions are selected, then the corresponding flag is set whenever a valid set or
clear condition is met. If the set and clear conditions are true at the same time, the flag will clear. The same
functionality is applied to the
[TD]
and
[FD]
bits in
GaugingStatus()
.
Note
GaugingStatus[TC][TD][FC][FD]
are the status flags based on the gauging conditions only. These
flags are set and cleared based on
SOCFlagConfigA
and
SOCFlagConfigB
.
The
BatteryStatus[TCA][TDA][FC][FD]
flags will be set and cleared according to the
GaugingStatus[TC][TD][FC][FD]
flags, as well as the safety and permanent failure protections status.
The table below summarizes the options to set and clear the
[TC]
and
[FC]
flags in
GaugingStatus()
.
Flag
Set Criteria
Set Condition
Enable
[TC]
Cell Voltage
Max cell voltage1..2 ≥
TC: Set Voltage
Threshold
SOCFlagConfigA[TCSetV]
= 1
RSOC
RelativeStateOfCharge()
> =
T
C: Set %
RSOC Threshold
SOCFlagConfigA[TCSetRSOC]
= 1
Valid Charge Termination
(enable by default)
When
ChargingStatus[VCT]
= 1
SOCFlagConfigA[TCSetVCT]
= 1
[FC]
Cell Voltage
Max cell voltage1..2 ≥
FC: Set Voltage
Threshold
SOCFlagConfigB[FCSetV]
= 1
RSOC
RelativeStateOfCharge()
> =
FC: Set %
RSOC Threshold
SOCFlagConfigB[FCSetRSOC]
= 1
Valid Charge Termination
(enable by default)
When
ChargingStatus[VCT]
= 1
SOCFlagConfigA[FCSetVCT]
= 1
Flag
Clear Criteria
Clear Condition
Enable
[TC]
Cell Voltage
Max cell voltage1..2 ≤
TC: Clear Voltage
Threshold
SOCFlagConfigA[TCClearV]
= 1
RSOC (enable by default)
RelativeStateOfCharge()
≤
TC: Clear %
RSOC Threshold
SOCFlagConfigA[TCClearRSOC]
= 1
Advanced Charge Algorithm
26
BQ28Z610-R2
Copyright © 2022 Texas Instruments Incorporated