2.9 Overtemperature in Discharge Protection
The device has an overtemperature protection for cells in DISCHARGE or RELAX state (that is, non-charging
state with
BatteryStatus[DSG]
= 1).
Status
Condition
Action
Normal
Temperatures()
<
OTD:Threshold
OR charging
SafetyAlert()[OTD]
= 0
Alert
Temperatures()
≥
OTD:Threshold
AND not charging (that is,
BatteryStatus[DSG]
= 1)
SafetyAlert()[OTD]
= 1
BatteryStatus()[TDA]
= 1
Trip
Cell Temperature in
Temperatures()
≥
OTD:Threshold
AND not charging
(that is,
BatteryStatus[DSG]
= 1) for
OTD:Delay
duration
SafetyAlert()[OTD]
= 0
SafetyStatus()[OTD]
= 1
BatteryStatus()[OTA]
= 1
OperationStatus()[XDSG]
= 1
BatteryStatus()[TDA]
= 0
Recovery
SafetyStatus()[OTD]
AND Cell Temperature in
Temperatures()
≤
OTD:Recovery
SafetyStatus()[OTD]
= 0
BatteryStatus()[OTA]
= 0
OperationStatus()[XDSG]
= 0
BatteryStatus()[TDA]
= 0
2.10 Undertemperature in Charge Protection
The device has an undertemperature protection for cells in charge direction.
Status
Condition
Action
Normal
Temperatures()
>
UTC:Threshold
OR not charging
SafetyAlert()[UTC]
= 0
Alert
Temperatures()
≤
UTC:Threshold
AND charging
SafetyAlert()[UTC]
= 1
Trip
Temperatures()
≤
UTC:Threshold
AND charging for
UTC:Delay
duration
SafetyAlert()[UTC]
= 0
SafetyStatus()[UTC]
= 1
OperationStatus()[XCHG]
= 1
Recovery
SafetyStatus()[UTC]
AND
Temperatures()
≥
UTC:Recovery
SafetyStatus()[UTC]
= 0
OperationStatus()[XCHG]
= 0
2.11 Undertemperature in Discharge Protection
The device has an undertemperature protection for cells in DISCHARGE or RELAX state (that is, non-charging
state with
BatteryStatus[DSG]
= 1).
Status
Condition
Action
Normal
Temperatures()
>
UTD:Threshold
OR charging
SafetyAlert()[UTD]
= 0
Alert
Temperatures()
≤
UTD:Threshold
AND not charging (that is,
BatteryStatus[DSG]
= 1)
SafetyAlert()[UTD]
= 1
Trip
Temperatures()
≤
UTD:Threshold
AND not charging (that is,
BatteryStatus[DSG]
= 1) for
UTD:Delay
duration
SafetyAlert()[UTD]
= 0
SafetyStatus()[UTD]
= 1
OperationStatus()[XDSG]
= 1
Recovery
SafetyStatus()[UTD]
AND
Temperatures()
≥
UTD:Recovery
SafetyStatus()[UTD]
= 0
BatteryStatus()[OTA]
= 0
OperationStatus()[XDSG]
= 0
2.12 Precharge Timeout Protection
The device can measure the precharge time and stop charging if it exceeds the adjustable period.
Status
Condition
Action
Enable
Current()
>
PTO:Charge Threshold
AND
ChargingStatus()[PV]
= 1
Start PTO timer
SafetyAlert()[PTOS]
= 0
Suspend or Recovery
Current()
<
PTO:Suspend Threshold
Stop PTO timer
SafetyAlert()[PTOS]
= 1
Protections
SLUUCO0 – APRIL 2022
BQ28Z610-R2
17
Copyright © 2022 Texas Instruments Incorporated
Содержание BQ28Z610-R2
Страница 1: ...BQ28Z610 R2 Technical Reference Manual Literature Number SLUUCO0 APRIL 2022 ...