bq25970 PWR893 Evaluation Module
5. Turn on the computer. Launch
Battery Management Studio
(bqStudio). Select
Charger
and bq25970
evaluation software. The main window of the software is shown in
Figure 3. Select “Charger” in bqStudio Window
2.3
Test Procedure
The steps for the test procedure follow:
1. Ensure equipment setup steps are followed.
2. Launch the bq258970 EVM GUI software, if not already done.
3. Turn on PS and battery simulator.
4. Measure Input.
VAC(TP1) = 7.5 V ±0.2 V
VBUS(TP4) = 0 V, I_VBUS = 0 A
Measure
→
Output:
VOUT(TP17) = 3.6V ±0.2 V