Test Summary
8. Turn on the computer. Launch the bq2419xEVM evaluation software. The main window of the software
is shown in
.
Figure 3. Main Window of the bq24195x Evaluation Software for bq24195/L
2.3
Procedure
Follow the steps and verify the outputs and IC for the EVM.
2.3.1
Current Settings
1. Make Sure EQUIPMENT SETUP steps are followed.
ILIM Setting: Set the potentiometer to its lowest value for max input current by connecting an ohm-
meter between point TP9 and ground. Turn the screw on the potentiometer counterclockwise until the
resistance drops to its lowest point (approximately 169
Ω
, the value of R7)
2. Launch the BQ2419x EVM GUI software, if not already done
3. Turn on PS#1
Measure
→
V (J2(SYS), J2(GND)) = 4.10 ±300 mV
6
bq24195/L EVM (PWR193) User’s Guide
SLUUA18 – October 2012
Copyright © 2012, Texas Instruments Incorporated