Test Summary
2.2
Equipment Setup
1. Set PS#1 for 5-V DC, 1-A current limit and then turn off the supply.
2. Connect the output of PS#1 in series with a current meter (multimeter) to J1 (V
BUS
and GND).
3. Connect a voltage meter across J1 (V
BUS
) and J1 (GND).
4. Turn on the Load, set to constant voltage mode and output to 2.5 V. Turn off (disable) Load. Connect
Load in series with a current meter (multimeter), ground side, to J2 (BAT+ and GND) as shown in
5. Connect a voltage meter across J2 (BAT+ and GND).
6. Connect the HPA172 USB interface adapter to the computer with a USB mini-cable and to J3 with the
10-pin ribbon cable. The connections are shown in
Figure 1. Connections of the HPA172 Kit
shows the test setup for PWR193.
7. Install shunts as shown in
.
Figure 2. Original Test Setup for PWR193 (bq24195/L EVM)