Test Summary
lists the controls and key parameter settings for this EVM.
Table 2. Jumper Connections
Jack
Description
Factory Setting
JP1
TS1 to TS2 connection
Shunt installed
JP2
D- 20k pull down
Shunt not installed
JP3
VSYS pull-up for STAT, CE, INT
Shunt installed
JP4
USB current limit selection pin during buck mode and PSEL is high (JP1-High);
Shunt not installed
enable pin during boost mode.
In buck mode: OTG = High, I
IN
limit = 500 mA;
OTG = Low, I
IN
limit = 100 mA.
The boost mode is activated when the REG01[5:4] = 10 and OTG pin is HIGH.
JP5
/CE pin setting: Pull low to enable the charge
Shunt not installed
(GUI also can pull CE low)
JP6
200-
Ω
short between D+ and D-
Shunt not installed
JP7
TS2 resistor divider pull-up source (REGN) connection
Shunt installed
JP8
Internal 10k to ground to TS2
Shunt installed
JP9
D+ 20k Pull down
Shunt not installed
lists the recommended operating conditions for this EVM.
Table 3. Recommended Operating Conditions
Symbol
Description
MIN
TYP
MAX
Unit
Supply voltage, V
IN
Input voltage from AC adapter input
3.9
5/12
6
V
Battery voltage, V
BAT
Voltage applied at V
BAT
terminal
0
3.7
4.25
V
Supply current, I
AC
Maximum input current from AC adapter
0
3
A
input
Output current, I
OUT
Output current
0
4
A
Operating junction temperature
0
125
°C
range, T
J
2
Test Summary
–
explain the equipment, the equipment setup, and the test procedures.
2.1
Equipment
2.1.1
Power Supplies
Power supply #1 (PS#1): a power supply capable of supplying 5 V at 1 A is required. While this part can
handle larger voltage and current, it is not necessary for this procedure.
2.1.2
Load #1 (4-Quadrant Supply, Constant Voltage < 4.5 V)
A 0–20 V/0–5 A, > 30-W system, DC electronic load and setting as constant voltage load mode.
Or:
Kepco load: BOP 20–5M, DC 0 to ±20 V, 0 to ±5 A (or higher)
Or:
Real single-cell battery
2.1.3
Load #2 – Use with Boost Mode
PMID-to-GND load, 10
Ω
, 5 W or greater
3
SLUUA18 – October 2012
bq24195/L EVM (PWR193) User’s Guide
Copyright © 2012, Texas Instruments Incorporated