background image

www.ti.com

Test Summary

Figure 2. BAT Load (PR1010) Schematic

2.2.3

Load #2 Between SYS and GND

Although not required, a resistive load capable of sinking up to 3 A can be used.

2.2.4

Meters

Four equivalent voltage meters (VMx) and two equivalent current meters (CMx) are required. The current
meters must be able to measure at least 3-A current.

2.3

Recommended Test Equipment Setup

1. For all power connections, use short, twisted-pair wires of appropriate gauge wire for the amount of the

current.

2. Set Power Supply number 1 for 6 V ± 100 mV, 3-A current limit, and then turn off supply.

3. If BAT_Load (PR1010) as shown in

Figure 2

is used, connect Power Supply number 2 (PS2) set to

approximately 3.6 V to the input side (PS2+/-) of BAT_Load (PR1010), then turn off PS2.

4. Connect the output side of the battery or BAT_Load (PR1010) in series with current meter (multimeter)

number 2 (CM2) to J2 and J6 or J3 (BAT, GND). Ensure that a voltage meter is connected across J2
or TP3 and J6 or TP9 (BAT, GND).

5. Connect VM3 across J5 or TP4 and J9 (SYS, GND).

6. Connect VM4 across J13 and J15 (DRV, GND).

7. Ensure jumpers are at the default factory settings per

Section 1.6

8. After the preceding steps are accomplished, the test setup for HPA741 is as shown in

Figure 3

7

SLUU497B – December 2011 – Revised June 2012

Chipscale-Packaged bq24165, 24166, 24167 Evaluation Modules

Submit Documentation Feedback

Copyright © 2011–2012, Texas Instruments Incorporated

Содержание bq24165

Страница 1: ...mended Operating Conditions 5 2 Test Summary 6 2 1 Definitions 6 2 2 Recommended Test Equipment 6 2 3 Recommended Test Equipment Setup 7 2 4 Recommended Test Procedure 8 3 Printed Circuit Board Layout Guideline 10 4 Bill of Materials and Board Layout 11 4 1 Bill of Materials 11 4 2 Board Layout 13 List of Figures 1 bq24165 166 167EVM HPA741 Schematic 3 2 BAT Load PR1010 Schematic 7 3 Original Test...

Страница 2: ... is a complete charger module for evaluating compact flexible high efficiency USB friendly switch mode battery charge and power path management solution for single cell Li ion and Li polymer battery powered systems used in a wide range of portable applications Key EVM features include Programmable charge current input current on and VINDPM threshold using jumpers Input power connectors for both US...

Страница 3: ...may have been assembled with incorrectly marked ICs Regardless of the IC s marking the EVM was assembled with the correct part number as specified in the EVM bill of material 3 SLUU497B December 2011 Revised June 2012 Chipscale Packaged bq24165 24166 24167 Evaluation Modules Submit Documentation Feedback Copyright 2011 2012 Texas Instruments Incorporated ...

Страница 4: ...l J12 GND Battery negative header J13 DRV DRV reference voltage positive header J14 DRV DRV reference voltage positive terminal J14 GND DRV reference voltage negative terminal J15 GND DRV reference voltage negative header J16 IN External thermistor positive terminal J16 GND Ground connection for external thermistor 1 5 Test Points Test Point Description TP1 Kelvin to IN TP2 Kelvin to USB TP3 SW TP...

Страница 5: ...mA input current limit and 4 68 V threshold 1 2 CE2 HI Active low enable for charging at half current if CE1 LO or suspended bq241 charging if CE1 HI JP6 2 3 CE2 LO 65 2 3 CE2 LO Active low enable for full current charging if CE1 LO or reduced VBAT voltage if CE1 HI 1 2 TS EXT Connects the TS pin to an external thermistor The resistor divider formed by bq241 R4 and R5 has been sized to accommodate...

Страница 6: ...rted Measure A B Check specified parameters A B If measured values are not within specified limits the unit under test has failed Observe A B Observe if A B occur If they do not occur the unit under test has failed Assembly drawings have location for jumpers test points and individual components 2 2 Recommended Test Equipment 2 2 1 Power Supplies 1 Power Supply number 1 PS1 capable of supplying 6 ...

Страница 7: ...hown in Figure 2 is used connect Power Supply number 2 PS2 set to approximately 3 6 V to the input side PS2 of BAT_Load PR1010 then turn off PS2 4 Connect the output side of the battery or BAT_Load PR1010 in series with current meter multimeter number 2 CM2 to J2 and J6 or J3 BAT GND Ensure that a voltage meter is connected across J2 or TP3 and J6 or TP9 BAT GND 5 Connect VM3 across J5 or TP4 and ...

Страница 8: ...meter number 1 CM1 to J2 IN GND 4 Connect voltage meter number 1 VM1 across J1 or TP1 and J3 or TP6 IN GND 5 With PS2 disabled turn on PS1 6 Measure Measure on VM3 V J5 TP4 SYS J9 GND 4 3 100 mV Measure on VM4 V J13 DRV J15 GND 5 2 200 mV 7 Move JP2 CE1 or CE LO and JP6 LO Adjust the power supply so that VM1 still reads 6 V 100 mV if necessary 8 Enable PS2 and adjust PS2 so that the voltage measur...

Страница 9: ...st PS2 so that the voltage measured by VM2 across BAT and GND measures 3 2 V 50 mV 9 Measure Measure on CM2 ICHRG 735 mA 75 mA Measure on CM1 IIN 475 mA 50 mA Observe D1 and D2 are on 10 Turn off PS1 and PS2 2 4 3 Helpful hints 1 To observe the taper current as the battery voltage approaches the set regulation voltage allow the battery to charge or if using BAT_Load PR1010 slowly increase the PS2 ...

Страница 10: ...urn of all components through vias two vias per capacitor for power stage capacitors one via per capacitor for small signal components It is also recommended to put vias inside the PGND pads for the IC if possible A star ground design approach is typically used to keep circuit block currents isolated high power low power small signal which reduces noise coupling and ground bounce issues A single g...

Страница 11: ...l Block 2 pin 6 A 3 5mm 0 27 x 0 25 ED555 2DS OST 6 6 6 JP1 JP2 JP3 JP4 JP5 PEC03SAAN Header Male 3 pin 100mil spacing 0 100 inch x 3 PEC03SAAN Sullins JP6 1 1 1 L1 1 5µH Inductor SMT 3 5A 70 mΩ 4 1 x 4 4 mm SPM4012T 1R5M TDK Alternate Toko Alternate FDSD0415 H 1R5M 1 1 1 Q1 CSD25401Q3 MOSFET PChan 20V 60A 8 7 mΩ chipscale3 3X3 3mm CSD25401Q3 TI 1 1 1 R1 26 7kΩ Resistor Chip 1 16W 1 603 Std Std 1 ...

Страница 12: ...RGER with 0 1 0 U1 BQ24166YFF IC 2 5A Dual Input Single Cell Switch mode Li Ion BGA BQ24166YFF TI BATTERY CHARGER with 0 0 1 U1 BQ24167YFF IC 2 5A Dual Input Single Cell Switch mode Li Ion BGA BQ24167YFF TI BATTERY CHARGER with 6 6 6 Shunt 100 mil Black 0 100 929950 00 3M 12 Chipscale Packaged bq24165 24166 24167 Evaluation Modules SLUU497B December 2011 Revised June 2012 Submit Documentation Feed...

Страница 13: ...ard Layout 4 2 Board Layout Figure 4 Top Assembly Layer Figure 5 Top Layer 13 SLUU497B December 2011 Revised June 2012 Chipscale Packaged bq24165 24166 24167 Evaluation Modules Submit Documentation Feedback Copyright 2011 2012 Texas Instruments Incorporated ...

Страница 14: ...ti com Figure 6 Bottom Layer Figure 7 First Internal Layer 14 Chipscale Packaged bq24165 24166 24167 Evaluation Modules SLUU497B December 2011 Revised June 2012 Submit Documentation Feedback Copyright 2011 2012 Texas Instruments Incorporated ...

Страница 15: ...and Board Layout Figure 8 Second Internal Layer 15 SLUU497B December 2011 Revised June 2012 Chipscale Packaged bq24165 24166 24167 Evaluation Modules Submit Documentation Feedback Copyright 2011 2012 Texas Instruments Incorporated ...

Страница 16: ...ency energy and has not been tested for compliance with the limits of computing devices pursuant to part 15 of FCC or ICES 003 rules which are designed to provide reasonable protection against radio frequency interference Operation of the equipment may cause interference with radio communications in which case the user at his own expense will be required to take whatever measures may be required t...

Страница 17: ... its gain should be so chosen that the equivalent isotropically radiated power e i r p is not more than that necessary for successful communication This radio transmitter has been approved by Industry Canada to operate with the antenna types listed in the user guide with the maximum permissible gain and required antenna impedance for each antenna type indicated Antenna types not included in this l...

Страница 18: ...er you obtained the Technical Regulations Conformity Certification as provided in Radio Law of Japan with respect to this product Also please do not transfer this product unless you give the same notice above to the transferee Please note that if you could not follow the instructions above you will be subject to penalties of Radio Law of Japan Texas Instruments Japan Limited address 24 1 Nishi Shi...

Страница 19: ... property damage personal injury or death If there are questions concerning these ratings please contact a TI field representative prior to connecting interface electronics including input power and intended loads Any loads applied outside of the specified output range may result in unintended and or inaccurate operation and or possible permanent damage to the EVM and or interface electronics Plea...

Страница 20: ...for use in safety critical applications such as life support where a failure of the TI product would reasonably be expected to cause severe personal injury or death unless officers of the parties have executed an agreement specifically governing such use Buyers represent that they have all necessary expertise in the safety and regulatory ramifications of their applications and acknowledge and agre...

Страница 21: ...андарту ISO 9001 Лицензия ФСБ на осуществление работ с использованием сведений составляющих государственную тайну Поставка специализированных компонентов Xilinx Altera Analog Devices Intersil Interpoint Microsemi Aeroflex Peregrine Syfer Eurofarad Texas Instrument Miteq Cobham E2V MA COM Hittite Mini Circuits General Dynamics и др Помимо этого одним из направлений компании ЭлектроПласт является на...

Отзывы: