3 Setup Procedure
Figure 3-1. EVM Test Setup
Note
The HSDC Pro software must be installed before connecting the TSW14J57EVM to the PC for the first
time.
3.1 Install the High Speed Data Converter (HSDC) Pro Software
1. Download the most recent version of the HSDC Pro software from
www.ti.com/tool/dataconverterpro-sw
Follow the installation instructions to install the software.
3.2 Install the Configuration GUI Software
1. Download the Configuration GUI software from the EVM tool folder at
.
2. Extract files from the .zip file.
3. Run the executable file (
setup.exe
), and follow the instructions.
3.3 Connect the EVM and TSW14J57EVM
With the power off, connect the ADCxxDJxx00RFEVM to the TSW14J57EVM through the FMC connector as
shown in
. Ensure that the standoffs provide the proper height for robust connector connections.
3.4 Connect the Power Supplies to the Boards (Power Off)
1. Confirm that the power switch on the TSW14J57EVM is in the off position. Connect the power cable to a
12-V DC (minimum 3 A) power supply. Ensure the proper supply polarity by confirming that the outer surface
of the barrel connector is GND and the inner portion of the connector is 12 V. Connect the power cable to the
EVM power connector.
2. Confirm that the power switch for the ADC12DJ5200EVM's power supply is in the off position. Connect the
power cable to a 12-V DC (minimum 2 A) power supply. Ensure the proper supply polarity by confirming that
the outer surface of the barrel connector is GND and the inner portion of the connector is 12 V. Connect the
power cable to the EVM power connector.