High Performance RA-RFM RI-RFM-008B
February 2002
20
CAUTION:
Exceeding recommended maximum ratings may lead to
permanent damage of the RA-RFM.
The RA-RFM must not be operated in continuous transmit
mode when operated at full power output.
Install suitable heatsinks when operating the RA-RFM at
pulse widths smaller than 50%.
2.1 Recommended Operating Conditions
Table 9 shows the recommended operating conditions.
Table 9: Operating Conditions
Symbol
Parameter
min.
typ. max.
Unit
V_VSP
Supply voltage of transmitter power stage
7.0
14.0 24.0 V DC
I_VSP
Current consumption of transmitter power stage - refer to the
formula below
1.0
2.0
Apeak
P_VSP
Peak pulse power input to transmitter power stage (I_VSP *
V_VSP * Duty Cycle)
24
W
V_ANT Antenna
resonance
voltage
250
380
Vpeak
V_ANT-25 Antenna resonance voltage (Pulse width setting
≤
25%)
200
Vpeak
V_ANT-
ATI
Minimum antenna resonance voltage for correct operation of ATI 25
Vpeak
V_VSL
Supply voltage input for logic part
7.0
24.0 V DC
I_VD
External current load on internal regulated logic supply voltage
output
1.0
mA
T_oper
Operating free-air temperature range
-25
+70
° C
T_store
Storage temperature range
-40
+85
° C
Note:
Free-air temperature is the air temperature immediately surrounding
the RA-RFM module. If the module is incorporated into a housing, it
must be guaranteed by proper design or cooling that the internal
temperature does not exceed the recommended operating conditions.