15. Troubleshooting
Symptom
Possible causes
Possible solution
Green power indicator flashing
Low battery voltage
Charge the battery
Green power indicator always on
and motor stops running
Overloaded
The guide bar/chain is blocked.
Remove the battery from the machine.
Remove the guide bar from the tree and
restart the machine.
No chain lubrication
No oil in reservoir
Vent in oil filler cap clogged
Oil passage clogged
Refill oil
Clean cap
Clean oil passage outlet on machine
(behind guide bar) and clean the guide bar
groove
Chain/guide bar overheats
No oil in reservoir
Vent in oil filler cap clogged
Oil passage clogged
Chain is over tensioned
Dull chain
Refill oil
Clean cap
Clean oil passage outlet
Adjust chain tension screw
Sharpen chain or replace
Chainsaw rips, vibrates,
does not saw properly
Chain tension too loose
Dull chain
Chain worn out
Chain teeths are facing in the wrong
direction
Adjust chain tension screw
Sharpen chain or replace
Replace chain
Reassemble with chain in correct direction
For troubleshooting regarding battery and charger, see user manuals included for these items.