6.

 

To actuate press, position top platen over one of the bottom platens and depress the black 
pushbutton labeled “Start Cycle” located on the handle simultaneously with one of the 
black pushbuttons labeled “Start Cycle” located on either side of the swivel head.  Machine 
will cycle ONLY when the top platen is in position directly over a bottom platen.  When 
press cycle is in progress, the amber light on the control panel will turn on and remain on 
for all but the last two seconds of the timing cycle.  At that time, the amber light will go into 
a blinking mode to alert the operator that the press cycle is nearly complete. 

7.

 

To immediately open the press, push one of the red “Emergency Release” pushbuttons 
located on either side of the swivel head.  This safety feature bypasses the timer and 
immediately opens the press in case of an emergency.  Only one red pushbutton need be 
depressed to interrupt cycle.  Also, the press should open immediately if the power switch is 
turned “OFF” or if the machine power cord is unplugged. 

 

CONVERSION TABLE 

GAUGE 

PRESSURE 

TOTAL INTER-

PLATEN 

PRESSURE 

LBS. PSI 2” x 

4” PLATEN 

LBS. PSI 3” x 

5” PLATEN 

LBS. PSI 4” x 

6” PLATEN 

LBS. PSI 5” x 

6” PLATEN 

LBS. PSI 3 ¼” x 

5” EXTENDED 

ANVIL PLATEN 

25 

177 

22.1 

11.8 

7.4 

5.9 

10.9 

30 

212 

26.5 

14.1 

8.8 

7.1 

13.0 

35 

247 

30.9 

16.5 

10.3 

8.2 

15.2 

40 

283 

35.4 

18.9 

11.8 

9.4 

17.4 

45 

318 

39.8 

21.2 

13.2 

10.6 

19.6 

50 

353 

44.1 

23.5 

14.7 

11.8 

21.7 

55 

389 

48.6 

25.9 

16.2 

13.0 

23.9 

60 

424 

53.0 

28.3 

17.7 

14.1 

26.1 

65 

459 

57.4 

30.6 

19.1 

15.3 

28.2 

70 

495 

61.9 

33.0 

20.6 

16.5 

30.5 

75 

530 

66.2 

35.3 

22.1 

17.7 

32.6 

80 

565 

70.6 

37.7 

23.5 

18.8 

34.8 

85 

601 

75.1 

40.1 

25.0 

20.0 

37.0 

90 

636 

79.5 

42.4 

26.5 

21.2 

39.1 

95 

672 

84.0 

44.8 

28.0 

22.4 

41.4 

100 

707 

88.4 

47.1 

29.5 

23.6 

43.5 

105 

742 

92.7 

49.5 

30.9 

24.7 

45.7 

110 

778 

97.2 

51.9 

32.4 

25.9 

47.9 

115 

813 

101.6 

54.2 

33.9 

27.1 

50.0 

120 

848 

106.0 

56.5 

35.3 

28.3 

52.2 

 

Table A-1 

 

Maintenance 

 

 

Drain moisture trap on Air Filter / Regulator as often as necessary. 

 

Check sponge and teflon.  Replace if needed.