background image

Requirements

 

 

1.

 

Air – 25 PSI minimum / 120 PSI maximum 

2.

 

Electrical Requirements – 120v A.C. / 60 Cycle 

 

POWER CONSUMPTION 

PLATEN SIZE 

WATTS 

AMPS 

2” x 4” 

600 

3” x 5” 

800 

4” x 6” 

880 

7.3 

5” x 6” 

1680 

14 

3 ¼” x 5”   Extended Anvil 

440 

3.7 

 
 

Installation 

 

1.

 

Connect air supply to 1/8” NPT inlet located in back of the Air Filter / Regulator that is 
attached to the right side of the machine. 

2.

 

Plug in electrical cord to properly fused and grounded receptacle. 

 
 

Operation 

 

1.

 

Set Air Regulator at required gauge pressure: 25 PSI minimum / 120 PSI maximum.  To 
adjust regulator, pull up and turn black knob.  Clockwise increases pressure, counter-
clockwise decreases pressure.  When pressure is set, push down black knob to lock.  See 

table A-1

 to convert gauge pressure to total interplaten pressure and pounds of 

pressure per square inch on platen surface. 

2.

 

Check Air Filter Bowl located beneath Air Regulator and Gauge.  If water is visible in 
bowl, drain moisture by turning shaft, located on the bottom of the bowl, counter-
clockwise. 

3.

 

Flip power switch located on lower left side of machine to “ON”.  Green light on control 
panel indicates power is “ON”. 

4.

 

Set top and bottom platen temperature controls located on right side of control panel 
to desired setting.  Allow 10 minutes for platens to heat up.  While platens are heating, 
their corresponding red light on the control panel will remain on.  When platens reach 
desired temperature the red light will turn off momentarily.  As the temperature 
controllers phase on and off to maintain desired platen temperature, the red lights will 
phase on and off also.  Platen heat can be turned off individually by turning knob 
counter-clockwise until it clicks. 

5.

 

Set Timer Control located on lower left of control panel to desired cycle dwell time.  This 
time setting will repeat each press cycle until changed. 