background image

 

 

TIP866-TM-10 User Manual Issue 1.5 

Page 6 of 13 

1  Product Description 

The TIP866-TM-10 is a complete interface solution for the TIP866-10 (8 serial channels RS232), the 
TIP866-20 (8 serial channels RS422) and the TIP867-10 (8 serial channels RS485). The TIP866-TM-
10 comes with a TA106-10 cable (0.8m ribbon cable with 50 pin ribbon cable connectors). 

The 8 serial ports of the TIP866-10/-20 or the TIP867-10 are routed to 8 DB25 connectors located in 
the 6U/8TE front panel of the TIP866-TM-10. 

Jumper fields are provided for each channel to select the port configuration (DTE / DCE) for RS232   
(Jn1 / Jn2) or RS422 (Jn3 / Jn4) and to select termination for the RS422 receiver (Jn5: 5-6, 7-8) or 
RS485 (Jn5: 1-2, 3-4).  

A two pin screw terminal (X9) can be used to p5V to pin 9 of the DB25 connectors of channel 
1 to 8 and to supply the on board termination for RS422 and RS485. The +5V can be individually 
selected by jumper for each of the channels 1 to 8 (Jn5: 9-10).  

TXD, RXD, RTS, CTS and GND are supported for each of the  8  serial  channels  of  the  TIP866-10        
(RS232). Additionally DCD, DTR, RI and DSR are supported for channel 1 and 2.  

TXD+/-, RXD+/- and GND are supported for the TIP866-20 (RS422) and DX+/- and GND are 
supported for the TIP867-10 (RS485). 

This transition module can also be used with the IP-Octals. If the TIP866-TM-10 is used with the IP-
Octal RS232: do not connect jumpers on J11, J12, J21, J22: 9-10, 11-12, 13-14 and 15-16 because 
the IP-Octal RS232 does not support DCD, DTR, RI and DSR on serial channel 1 and 2. 

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Содержание TIP866-TM-10

Страница 1: ... 2007 D75866851 TEWS TECHNOLOGIES GmbH TEWS TECHNOLOGIES LLC Am Bahnhof 7 25469 Halstenbek Germany www tews com Phone 49 0 4101 4058 0 Fax 49 0 4101 4058 19 e mail info tews com 9190 Double Diamond Parkway Suite 127 Reno NV 89521 USA www tews com Phone 1 775 850 5830 Fax 1 775 201 0347 e mail usasales tews com Downloaded from Arrow com ...

Страница 2: ...eserves the right to change the product described in this document at any time without notice TEWS TECHNOLOGIES GmbH is not liable for any damage arising out of the application or use of the device described herein Style Conventions Hexadecimal characters are specified with prefix 0x i e 0x029E that means hexadecimal value 029E For signals on hardware products an Active Low is represented by the s...

Страница 3: ...tember 1997 1 1 Redesign January 1998 1 2 Add cable TA106 10 June 2002 1 3 Completion Technical Specification April 2003 1 4 New address TEWS LLC September 2006 1 5 Added details for Jumper Configuration July 2007 Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com ...

Страница 4: ...CRIPTION 6 2 TECHNICAL SPECIFICATION 7 3 CONNECTOR X1 PIN ASSIGNMENT 8 4 DB25 PIN ASSIGNMENT 10 5 CONNECTOR X9 PIN ASSIGNMENT 11 6 JUMPER CONFIGURATION 12 7 ASSEMBLY DRAWING 13 Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com ...

Страница 5: ...T OF DB25 CONNECTOR TIP866 TM 10 CHANNEL 1 AND 2 10 FIGURE 4 2 PIN ASSIGNMENT OF DB25 CONNECTOR TIP866 TM 10 CHANNEL 3 TO 8 10 FIGURE 5 1 PIN ASSIGNMENT OF X9 SCREW TERMINAL 11 FIGURE 6 1 JUMPER FIELD JN5 12 FIGURE 7 1 ASSEMBLY DRAWING 13 Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com ...

Страница 6: ...can be used to provide 5V to pin 9 of the DB25 connectors of channel 1 to 8 and to supply the on board termination for RS422 and RS485 The 5V can be individually selected by jumper for each of the channels 1 to 8 Jn5 9 10 TXD RXD RTS CTS and GND are supported for each of the 8 serial channels of the TIP866 10 RS232 Additionally DCD DTR RI and DSR are supported for channel 1 and 2 TXD RXD and GND a...

Страница 7: ...in ribbon cable connectors Power Supply 5V GND by 2 pin screw terminal Power only required to supply on board termination or to provide 5V to pin 9 of the DB25 connectors of channel 1 to 8 Fuse protected by a 1A Multifuse MTBF 301749h Figure 2 1 Technical Specification Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com ...

Страница 8: ... 17 TXD4 TXD4 DX4 18 RXD4 TXD4 DX4 19 RTS4 RXD4 nc 20 CTS4 RXD4 nc 21 GND GND GND 22 TXD5 TXD5 DX5 23 RXD5 TXD5 DX5 24 RTS5 RXD5 nc 25 CTS5 RXD5 nc 26 GND GND GND 27 TXD6 TXD6 DX6 28 RXD6 TXD6 DX6 29 RTS6 RXD6 nc 30 CTS6 RXD6 nc 31 GND GND GND 32 TXD7 TXD7 DX7 33 RXD7 TXD7 DX7 34 RTS7 RXD7 nc 35 CTS7 RXD7 nc 36 GND GND GND 37 TXD8 TXD8 DX8 38 RXD8 TXD8 DX8 39 RTS8 RXD8 nc Downloaded from Arrow com...

Страница 9: ... nc 46 DSR1 nc nc 47 DCD2 nc nc 48 DTR2 nc nc 49 RI2 nc nc 50 DSR2 nc nc nc not connected on the TIP866 TM 10 Figure 3 1 Connector X1 Pin Assignment Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com ...

Страница 10: ... TIP866 TM 10 Channel 1 and 2 Pin No DB25 RS232 DTE Jn1 RS232 DCE Jn2 RS422 DTE Jn3 RS422 DCE Jn4 RS485 Jn3 2 TXD RXD TXD RXD DX 3 RXD TXD RXD TXD 4 RTS CTS 5 CTS RTS 7 GND GND GND GND GND 9 5V 5V 5V 5V 5V 14 TXD RXD DX 16 RXD TXD Figure 4 2 Pin Assignment of DB25 Connector TIP866 TM 10 Channel 3 to 8 Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arr...

Страница 11: ...Assignment of X9 Screw Terminal Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com ...

Страница 12: ... TIP866 TM 10 all jumpers installed on Jn1 RS232 DTE Jn5 is used for enabling an on board 120R termination resistor for the RS422 and RS485 modes If on board termination is desired only one termination block of jumper field Jn5 must be installed at a time Either 1 2 3 4 for the RS485 mode or 5 6 7 8 for the RS422 modes If RS232 modes are selected or on board termination is not desired leave Jn5 1 ...

Страница 13: ...w com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com ...

Отзывы: