Version: Leo 18 GT_GB_02-2008
43
/
16
Photo from profiles which are arranged “A” form and
from the securing pins
3.1.3 Safety devices
The safety operating of the machine is controlled by the following safety systems
•
Check valves which are controlled by pressure and placed on all working cylinder
•
Pressure limiting valve for three hydraulic cycles
-
supports and rubber foots for transporting: 200 bar
-
operating the superstrucrure: 140 bar
•
Basket sensor (the superstructure is only able to operate in case of the properly
assembled basket.)
•
The bubble glass, which is placed nearby the hand control valves, will help to
bring to the level the frame
•
The switch clock for eliminating of the spontaneous starting
•
The end switches, which are in the ground plates, control the safety stabilizing
•
Sensors controlling the angle of the bottom arm
•
Sensors controlling the end position of the bottom telescope
•
FI relay (30mA),
•
EMERGENCY-STOP switch on the switchboard of the basket and the cord
controlled remote-control panel
•
Two levelling switches assure to remain the basket to the level. The one /
operating switch/ will allow the tilt of the basket to 3°, after that, the control will
bring to the level the basket. The safety switch in case of the failure of the
operating switch/ will stop the elevating machine after ± 10° and, after that, the
machine can only be moved by emergency control.
•
Two levelling switches ensure the proper aligning of the vertical arm. The one /
operating switch/ will allow the tilt of the basket to 3°, after that, the control will
bring to the level the basket. The safety switch in case of the failure of the
operating switch/ will stop the elevating machine after ± 10° and, after that, the
machine can only be moved by emergency control.