background image

Product description

14

Product description

At a glance

 

 Protection cap: Park position

 

 Sensing electrodes

 

Caution!

 Risk of injury 

from sensing electrodes!

>

  Attach protection cap 

when not in use.

  Humidity/temperature sensor

  Display

 Control keys

  Battery compartment (on rear)

   Test resistance contact

 List of settable materials, for 

sticking into the protective cap

First steps

 Inserting batteries:

1

  To open the battery compartment, push the battery cover 

down.

2

  Insert batteries (2x 1.5 V type AAA). Observe the polarity!

3

  To close the battery compartment, push the battery cover 

back on.

 Basic settings (configuration mode):

Adjustable functions

·  Unit of temperature: 

°C

°F

·  Unit of humidity: 

%

td

 (dew point), 

WB

 (wet bulb)

·  Auto off function: 

OFF

ON

 (instrument switches off automatically if no key is 

pressed for 10 minutes)

1

  When switching the instrument on, press and hold   until 

 and 

 appear on the display (configuration mode).

-  The adjustable function is displayed. The current setting 

flashes.

Содержание 606-2

Страница 1: ...Instruction manual testo 606 2 99 Washington Street Melrose MA 02176 Phone 781 665 1400 Toll Free 1 800 517 8431 Visit us at www TestEquipmentDepot com...

Страница 2: ...Basic settings Instrument off press and hold 2s select with confirm with Unit of temperature C F Unit of humidity td dew point WB wet bulb Auto off function OFF ON Switching the instrument on Press S...

Страница 3: ...sures indicated are not taken Important Avoid personal injury damage to equipment Only operate the measuring instrument properly for its intended purpose and within the parameters specified in the tec...

Страница 4: ...materials rH td wb C F Measuring ranges 10 50 C 14 122 F 0 100 rH Material moisture See chapter Using the Product Resolutions 0 1 0 1 C 0 1 F 0 1 rH Accuracies Nominal temperature 25 C 1 Digit Conduct...

Страница 5: ...teries 1 To open the battery compartment push the battery cover down 2 Insert batteries 2x 1 5 V type AAA Observe the polarity 3 To close the battery compartment push the battery cover back on Basic s...

Страница 6: ...o 5 mm When measuring fuel moisture content it is advisable to split the log prior to measurement and to measure at three points Measuring points each 5 cm away from the left and right cut edge and on...

Страница 7: ...ect sensing electrodes with the contacts of the test resistor on the top of the protection cap Test flashes Test ok lights up instrument is functioning Test ok does not light up test not possible see...

Страница 8: ...tened the measurement results should always be within the measuring range Residual capacity 10 min Change batteries Testing the instrument function Test ok does not light up Clean sensing electrodes a...

Страница 9: ...3 3 5 5 Characteristic curve 3 Concrete 2 2 2 2 4 4 4 4 Characteristic curve 4 Anhydrite screed 0 5 0 5 1 1 Characteristic curve 5 Cement mortar 3 3 5 5 Characteristic curve 6 Lime mortar 2 2 4 4 Cha...

Страница 10: ...0973 6062 de en fr es it pt ru 05 Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 TestEquipmentDepot com...

Отзывы: