![TESTO 325M Скачать руководство пользователя страница 35](http://html.mh-extra.com/html/testo/325m/325m_instruction-manual_1092266035.webp)
Short instructions
35
Short instructions for
testo 325 M / XL
Please also follow instructions in Instruction manual
Connections
➀
Mains unit
➁
Probes: Ambient air
temperature (AT) / temperature T2
➂
Probes: Flue gas temperature
(FT) / Temperature T1
➃
Flue gas inlet (red)
➄
Pr (blue)
➅
Pressure - (p-)
Switching on instrument and selecting fuel
1 Switch on analyser via
.
- The following appear:
display test, software version/
power, zeroing phase.
- Instrument changes to fuel
selection.
2 Set fuel using
or
and confirm selection by pressing
.
- Instrument changes to measurement menu and is ready to operate.
Switching off analyser
1 Press
to switch off analyser.
2 Wait on automatic rinse.
-
OFF
is displayed for 5 s and then the analyser switches off.
Switching background light on/off
Switch background light on or off by pressing
.
Selecting menu item
1 Open main menu by pressing
.
2 Use
/
to select menu item and confirm selection via
.
If sub-menu is available:
3 Select menu item via
/
and press
to confirm.
Press
to go back one menu level.
Setting date/time
1 Select
Dat/Clk
in main menu and press
to confirm.
2 Set value via
/
, change to next value via
.
3 Press to
confirm
settings.
➂
➃
➁
➄
➀
➅