8 Tips and assistance 

 

 

35

 

Description  

Article no. 

Temperature surface probe TC type K, can be 
attached to 0430 0143 and 0430 0145 

0604 0194 

Line plug-in head probe for probe 0604 0194, 
length 1.5 m 

0430 0143 

Line plug-in head probe for probe 0604 0194, 
length 5 m 

0430 0145 

Hose set for testo 312-4 

0554 3172 

Pressure connection hose set, coiled 

0554 0441 

Pressure set for gas pressure measurement on 
heating units 

0554 0449 

LW6 connection hose 

0554 3158 

Balloon pump with bleed screw 

0554 3173 

Single pipe counter cap, connects test set to 
pipe 

0554 3156 

Dual valve connector for the connection of two or 
more pipes 

0554 3161 

Single valve stop for blocking off the pipe 

0554 3162 

Conical test stop 1/2" 

0554 3151 

Conical test stop 3/4" 

0554 3155 

High-pressure stage stop 3/8" and 3/4" 

0554 3163 

High-pressure stage stop 1/2" and 1" 

0554 3164 

IR protocol printer 

0554 0547 

Spare thermal paper (6 rolls) 

0554 0568 

Connection line for high-pressure probes 
0638 1741, 0638 1841, 0638 1941, 0638 2041, 
0638 2141 

0409 0202 

Adapter for pressure probes 

0699 3127 

High-pressure probe to 25 bar 

0638 1743 

Leak detection spray to detect leaks in gas pipes 0554 3166 
Table mains unit with international connection 

0554 1143 

Test pump for setting the test pressure 

0554 3157 

9 volt rechargeable battery for testo 312-4 

0515 0025 

Battery charger for 9 V rech. battery, for external 
charging of rech. battery 

0554 0025 

Содержание 312-4

Страница 1: ...testo 312 4 Pressure measuring instrument Instruction manual...

Страница 2: ...2...

Страница 3: ...eps 14 6 Using the product 15 6 1 Performing settings 15 6 1 1 Location 16 6 1 2 Memory 16 6 1 3 Instrument 18 6 1 4 Service 19 6 1 5 Input 21 6 1 6 Gas type 23 6 2 Measuring 23 6 2 1 Important inform...

Страница 4: ...1 Contents 4 7 Maintaining the product 33 8 Tips and assistance 34 8 1 Questions and answers 34 8 2 Accessories and spare parts 34...

Страница 5: ...ubsequent users of the product Symbols and writing standards Representation Explanation Warning advice risk level according to the signal word Warning Serious physical injury may occur Caution Slight...

Страница 6: ...maintenance and repair work on this instrument that is described in the documentation Follow the prescribed steps exactly Use only original spare parts from Testo Temperatures given on probes sensors...

Страница 7: ...essure at gas meter Monitoring of gas flow pressure at gas meter Setting the nozzle pressure for setting gas burners heaters Water pipes Leak test of wastewater disposal lines in acc with DIN EN 1610...

Страница 8: ...ace Infrared Measurement data memory approx 25000 readings Battery running time in continuous operation with internal pressure sensor 30 h with alkali manganese at 25 C 77 F Sensor piezoresistive Stor...

Страница 9: ...tions 1 IR interface for protocol printer 2 Keyboard Key Function Print Select reading 1 top line select menu item Switching on off Saving data Open menu level confirm selection execute function Zero...

Страница 10: ...onnections Connection Function 1 Socket 1 Thermocouple probe type K NTC probe pressure probe 2 Socket 2 Thermocouple probe type K NTC probe pressure probe RS 232 PC connection 12 V DC 12 V DC mains un...

Страница 11: ...e cleared Lights up printing possible Flashes print function activated Rechargeable battery battery charge level The black segments go out with a decreasing residual capacity Flashes Battery rechargea...

Страница 12: ...on the function Level 1 Level 2 Level 3 1 Measurements 11 Pretest 12 LeakRate 13 Maintest 2 Location 3 Memory 31 Man Auto 32 Config 33 Print 34 Status 35 Delete 4 Instrument 41 Time 42 Auto Off 43 Un...

Страница 13: ...asic properties Voltage supply The power can be selectively supplied to the testo 312 4 via 9 V monobloc battery type IEC 6LR61 included in delivery 9 V monobloc rechargeable battery type NiMH IEC 6F2...

Страница 14: ...are secure but do not use force Connect thermocouple probe type K NTC probe pressure probe at socket 1 and socket 2 Connect pressure tubes to and Caution Danger of injury caused by the pressure tube j...

Страница 15: ...ected externally the measurement of the internal sensor is deactivated Left probe socket upper line Right probe socket lower line p With or calculated differential pressure pressure temperature is dis...

Страница 16: ...location is created when the unit is first commissioned Up to 98 additional locations can be added 4 Confirm the selection with 6 1 2 Memory 1 Use or in main menu to select Memory and confirm selecti...

Страница 17: ...g or Hold the key down to go forward back quickly The duration of the measurement series is displayed in the upper line for your information 4 Confirm the selection with Set Fast measurement program i...

Страница 18: ...n menu to select Device and confirm selection with 2 Select the required function menu with or and confirm with 3 Use to activate setting mode Time Time and date can be set 1 Set hour with or hh Hold...

Страница 19: ...ative pressure probes with measuring range 1 to 25 bar C F temperature 1 Select ISO US with or and confirm the selection with 2 Select ISO or US with or and confirm selection with 3 Select P Low P Hig...

Страница 20: ...chBatt if a rechargeable battery is actually fitted in the instrument Select Battery or RechBatt using or and confirm selection with Factory reset The instrument settings can be reset to the condition...

Страница 21: ...function with or 3 Use to activate setting mode Pretest LeakRate Maintest The stabilization time slowdown time before the test time and the measurement period test time can be set for the pretest lea...

Страница 22: ...m can be entered from which three partial volumes can be calculated The performance volume is calculated by adding the three partial volumes together 1 Use or to select Circle 1 2 Confirm the selecti...

Страница 23: ...gas Nat gas or Air with or 4 Confirm the selection with 6 2 Measuring 6 2 1 Important information for pressure measurement Temperature fluctuations and positional changes have an effect on the accurac...

Страница 24: ...g with pressure test set by plugging it into the single valve stop Caution Damage to the sensoring technology in the event of exceeding the permissible pressure Do not subject the measuring instrumen...

Страница 25: ...6 Using the product 25 Pretest and high pressure at water pipes 1 High pressure probe 2 Pressure test set 3 High pressure stage stop 4 Compressor...

Страница 26: ...and there must be a differential pressure of 2 5h Pa Please refer to the instruction manual of the pressure probe for the zeroable range of the external pressure probes Zero the display values of the...

Страница 27: ...t measurement is only possible with pressure probes or an internal pressure sensor Only 1 channel can be evaluated and the following sequence applies external pressure sensor before internal pressure...

Страница 28: ...as the following measuring functions Hold value Hold The last readings are held in the display Display maximum value Max The highest readings since the start of measurement are displayed Display minim...

Страница 29: ...with 1 bar and the pressure may not drop within 10 minutes The measurement is performed using a high pressure probe 25 bar The main test using air or inert gas e g CO2 or N2 is used for the leak test...

Страница 30: ...ime with or and confirm with 5 Select Meastime with or and confirm with 6 Set Meastime with or and confirm with 7 Confirm Finish message with Begin measurement procedure 1 Open the stop valve of the p...

Страница 31: ...itres per hour at operating pressure According to the degree of usability the following measures must be carried out 1 If there is unlimited usability the pipes can still be used 2 If there is diminis...

Страница 32: ...Hold the key down to go forward back quickly 9 Confirm the selection with 10 To set other values Length 1 for first partial volume Circle 2 und Length 2 for second partial volume Circle 3 and Length 3...

Страница 33: ...g process if a rechargeable battery is in the instrument and the battery type is set to RechBatt 1 Check if a rechargeable battery is in the instrument 2 Check if the battery type is set to RechBatt 3...

Страница 34: ...y save the readings PC software printout 8 2 Accessories and spare parts Description Article no testo 316 1 gas leak detector 0632 0316 Differential pressure probe 100 Pa 0638 1347 Differential pressu...

Страница 35: ...two or more pipes 0554 3161 Single valve stop for blocking off the pipe 0554 3162 Conical test stop 1 2 0554 3151 Conical test stop 3 4 0554 3155 High pressure stage stop 3 8 and 3 4 0554 3163 High p...

Страница 36: ...tance 36 Description Article no TopSafe for testo 312 4 0516 0446 Magnetic holder for TopSafe 0554 0225 Easyheat PC software 0554 3332 RS232 cable connecting measuring instrument to PC 0409 0178 Syste...

Страница 37: ......

Страница 38: ...0970 3126 en 06 V01 05...

Отзывы: