TESTING DT-202 Скачать руководство пользователя страница 9

§1

 

Summary of equipment 

 

§1

 

Summary of equipment   

 
This tester is used to test the shock resistance of a small and lightweight product (portable telephones, etc.) 
by freely dropping it from the height of 250~ 2200mm 

1

  while holding it under an optional position.   

 
1-1

 

Specimen supporting base   
This specimen supporting  base is used to support a  specimen and  freely drop  it from an optional 
height.    It is provided with pneumatic pen cylinders to be able to release the specimen momentarily 
at a specified position.   

 
1-2

 

Fixing and drop operation of specimen   
A specimen is set by [SET] and [RESET] push-button switches of the control unit.    The specimen is 
dropped by [DROP] push-button switch.   

 
1-3

 

Drop height setting   
The drop height can be set by setting the height setting bracket to an optional scale position of the 
scale.   

 
1-4

 

Safety measures of operation   
The control system is designed by taking a serious view of safety.   

 

1)

 

When the pneumatic cylinders are set to the pull side, the drop operation is not done even if [DROP] 
push-button switch is pressed.   

 

2)

 

Drop operation is done by [DROP] push-button switch.    An alarm buzzer sounds when pressing this 
switch and s specimen drops when releasing the switch.   

 

3)

 

If a trouble was detected when the buzzer is sounding by pressing [DROP] push-button switch, turn 
off  [POWER]  switch  without  releasing  [DROP]  push-button  switch,  and  the  drop  operation  is  not 
done.   

 

4)

 

The electromagnetic holder for dropping a specimen is operated by feeding its power supply so that 
no specimen drops when power was interrupted to ensure safe operation.    The pneumatic cylinders 
(solenoid  valves)  for  releasing  the  specimen  are  also  operated  by  feeding  power,  so  that  no 
specimen  drops  when  power  was  interrupted  to  ensure  safe  operation  so  long  as  the  pneumatic 
pressure is supplied normally.   

 

                                                

1

 

250-500mm: In this range specimen can be just released from the setting height while chuck itself would be

 

stay at 

setting height.

 

Содержание DT-202

Страница 1: ...DT 202_007 Operation Manual for Drop Tester Model DT 202 SHINYEI TESTING MACHINERY CO LTD...

Страница 2: ......

Страница 3: ...ence of this display during work may cause personnel death or serious injuries Observe the instruction contents Negligence of this display during work may cause a fire an electric shock accident or ot...

Страница 4: ...the control unit from the case during test otherwise it may cause ingress of foreign substances to result in a trouble It is possible that parts are replaced and checked due to unavoidable circumstan...

Страница 5: ...tester base interior 6 A specimen may tilt down in an unexpected direction due to drop collision Particularly be careful since certain specimens may be broken to scatter 7 If the cover is removed from...

Страница 6: ...X 81 78 332 1619 NAGOYA OFFICE Nishiki emuai BLDG 5F 1 7 39 Nishiki Nakaku Nagoya Aichi 460 0003 Japan Tel 81 52 218 5472 Fax 81 52 218 6112 For inquiries through telephone Monday to Friday Excluding...

Страница 7: ...5 4 4 Specimen supporting base 5 4 5 Height setting pointer 5 4 6 Pneumatic pen cylinders for fixing and releasing a specimen 5 4 7 Contacts 5 4 8 Pneumatic regulator 6 5 Operation method 7 5 1 Contro...

Страница 8: ......

Страница 9: ...is designed by taking a serious view of safety 1 When the pneumatic cylinders are set to the pull side the drop operation is not done even if DROP push button switch is pressed 2 Drop operation is do...

Страница 10: ...2 Outer View 2 2 Outer View Fig 1...

Страница 11: ...ithout fails 2 Pneumatic pressure source Pneumatic pen cylinders are used for fixing a specimen Feed the air pressure from the compressor2 option or indoor piping higher than 0 49MPa in a building The...

Страница 12: ...for fixing a specimen in particular for normal condition before starting the test See Fig 2 3 Drop height setting Set the height setting pointer to an optional position of the scale and fix it by fast...

Страница 13: ...specimen supporting base is provided with two pneumatic pen cylinders for fixing and releasing a specimen The drop height is set to the center axis of these pneumatic pen cylinders 4 5 Height setting...

Страница 14: ...ders for fixing and releasing a specimen Please set it over 0 49MPa at least Fig 4 2 SET adjusting speed controller This speed controller is mounted on the pneumatic pen cylinders This airflow regulat...

Страница 15: ...pneumatic pen cylinders are controlled to fix the specimen when the power supply has been turned off 2 DROP push button switch This push button switch is used for dropping a specimen A specimen must...

Страница 16: ...5 Operation method 8 Fig 6 Control unit...

Страница 17: ...ecimen Memo If the drop height is lower than 500mm the releasing operation does not function even if the switch is set to DH 500mm Set the switch to DH 500mm without fail Memo An automatic drop height...

Страница 18: ...2 Check if the metal connector Co 2 on the rear panel of the control unit is connected See 9 1 Wiring diagram 6 3 Pneumatic pen cylinders don t operate 1 Check if the metal connector Co 1 on the rear...

Страница 19: ...ISO VG10 may cause dust to be attached easily more or less Wipe off the guide rail by a clean cloth without fail after use 7 2 The operation may change due to dust etc after a long time use Check the...

Страница 20: ...nsions 600mm in width 500mm in depth 2382mm in height 8 Tester weight approx 110kg 9 Painting color Body Munsell code 10B5 10 Japan Painting Industrial Association B69 50T Control unit Munsell code N9...

Страница 21: ...8 Performance and specifications 13 8 4 Attachments 1 Single ended wrench 8mm across flats 1 pc 2 Test data 1 copy 3 Operation manual 1 copy Fig 7 Maximum specimen size...

Страница 22: ...9 Diagram 14 9 Diagram 9 1 Wiring diagram...

Страница 23: ...e filter S 5 Manual switch M 2011 Nikkai 1 Single pole double throw Guard cover for Drop switch AL KH6 IDEC 1 PL 1 Power lamp S1 1 DC DC Converter CCK 2405SF TDK 1 24VDC 5VDC RC Spark killer XE1201 3...

Страница 24: ...9 Diagram 16 9 3 Pneumatic piping diagram...