background image

  
Air Entrainment Meters  

0.5   litre; model: TESTING 1.0334          0,75  litre; model: TESTING 1.0337 

 

1      litre; model: TESTING 1.0335           5  litre; model: TESTING 2.0332 

7      litre; model: TESTING 2.0337           8  litre; model: TESTING 2.0334 

 

  

  

Page 33 of 42 pages  

6.8   List of spare parts for the 5-litre 

5-litre TESTING air entrainment meter, manual, model no.: 2.0332 

 

Item 

 

 

Article no. 

 

 

Qty. 

 

 

Designation  

 

  

Parts, inclusive 

 

1.  

2.0332  

1  

Air entrainment meter, complete  

  

2.  

2.0332-O  

1  

Upper part  

Hand pump, switch plate, clamping 

stud, pressure gauge, spacer, cap, 

chamber cover, valves, tubes  

3.  

2.0332-A1  

1  

Test pot, complete  

Clamping ring and handles  

4.  

2.0334-A1-02  

1  

Clamping ring and handles  

  

5.  

2.0334-A2-D  

1  

Chamber cover with O-ring  

diam. 200 x 5  

  

6.  

OR-200x5  

1  

O-ring for the cover  

  

7.  

Pn-001L  

1  

Ball shut-off valve, left, complete  

Cu seals (2 x 0.3 / 2 x 0.5)  

8.  

Pn-001R  

1  

Ball shut-off valve, right, complete  

Cu seals (2 x 0.3 / 2 x 0.5)  

9.  

2.0334-A2-02  

4  

Quick-release latch, complete  

2 ea. screws and spring  

10.  

2.0334-A4  

1  

Clamping stud, complete  

O-rings, nuts, hose fittings  

11.  

2.0332-A6  

1  

Pressure gauge  

Tube fittings, O-ring  

12.  

2.0334-MS  

1  

Spare-parts kit for the pressure gauge  

Threaded ring, disk, O-ring  

13.  

2.0334-A7-K  

1  

Hand pump, complete  

Switch plate, valves, tubes  

14.  

2.0334-A7-01  

1  

Pump jacket, complete  

  

15.  

2.0334-A7-P  

1  

Hand pump with bottom valve  

  

16.  

2.0334-A7-02  

1  

Pump rod, complete  

Pump sleeve  

17.  

LP-BT-01  

1  

Switch plate with cellular-rubber seal 

  

Screws, bolts  

18.  

LP-BT-02  

1  

Bottom valve  

  

19.  

LP-BT-03-T  

1  

TEST pushbutton  

Knurled nut, tube fitting  

20.  

LP-BT-03-C  

1  

CORRECTION pushbutton  

Knurled nut  

21.  

Pn-004  

1  

Regulating valve  

  

22.  

2.0334-DS  

1  

Sealing kit  

  

23.  

Pn-006  

1  

Tube, diam. 4 x 1  

2 m  

24.  

LP-PM-01  

1  

Pump sleeve  

  

25.  

2.0334-SS  

1  

Screw and bolt kit  

4 ea. countersunk-head screws; 3 ea. 

capnuts; 3 ea. U-washers  

26.  

LP-08-G  

1  

Rubber cap, green  

  

27.  

LP-08-S  

1  

Rubber cap, black  

  

  

 

Tube lengths for 5-litre TESTING air entrainment meter

 

 

Item 

 

Designation 

 

Length 

 

1.  

A-A  

265 mm  

2.  

B-B  

265 mm  

3.  

C-C  

265 mm  

4.  

D-cap  

155 mm  

5.  

E-E  

155 mm  

6.  

F-pressure gauge  

225 mm  

  

Содержание 1.0334

Страница 1: ...struction material testing devices Motzener Str 26b DE 12277 Berlin Germany Tel 49 0 30 710 964 5 0 Fax 49 0 30 710 964 5 98 www testing de Operating Manual Air Entrainment Meter 0 5 litre 0 75 litre...

Страница 2: ...ration of the system 10 1 6 2 Basic elements and characteristics of the air entrainment meters 11 2 The test procedure 14 3 Cleaning and maintenance 17 4 Checking and calibrating the air entrainment 1...

Страница 3: ...attention to danger that can lead to damage to equipment or other objects Danger This warning indicates danger that can lead to severe injury or death Note This warning gives practical instructions o...

Страница 4: ...hen this is authorized only after consultation with the manufacturer and after obtaining his prior and express approval The 0 5 litre air entrainment meter has been manufactured in accordance with the...

Страница 5: ...air entrainment meters are damaged or have any malfunctions that can impair their operational safety they must be immediately placed out of operation and the malfunctions must be corrected These syste...

Страница 6: ...f the meters Meter Weight when empty Weight when filled with mortar 0 5 litre air entrainment meter approx 3 8 kg approx 4 8 kg 0 75 litre air entrainment meter approx 3 9 kg approx 5 3 kg 1 litre air...

Страница 7: ...t you return the system to us for repair 1 4 2 Transport This system will be delivered in the specific cardboard boxes In order to prevent transport damage the remaining hollow spaces in the interior...

Страница 8: ...on Article number for the model 0 5 litre TESTING Article number for the model 0 75 litre TESTING Article number for the model 1 litre TESTING Article number for the model 5 litre TESTING Article numb...

Страница 9: ...truction sites 1 0335 02 1 0335 02 1 0335 02 2 0333 25 2 0333 25 2 0333 25 Straightedge for striking off 400 mm 2 0237 04 Aluminium poking rod 2 0237 03 Rubber hammer 400 g 8 0204 Rubber hammer 800 g...

Страница 10: ...se air entrainment meters have a pressure chamber in which a specified air pressure is produced by a hand pump When an overflow valve is opened pressure equalization is established with respect to the...

Страница 11: ...ainment meters The air entrainment meters consist of 2 main components I Upper part a Cap pressure gauge mount Switch panel with integrated manual pump TEST valve correction valve and pressure gauge b...

Страница 12: ...latches The water is filled in through the two ball shut off valves and air pressure release takes place through these same valves The compressed air is produced by a hand pump installed in the air en...

Страница 13: ...mm 180 dia x 316 mm 180 dia x 330 mm 220 dia x 490 mm 220 x 505 mm 220 dia x 600 mm Net weight 3 8 kg 3 9 kg 4 0 kg 8 7 kg 9 1 kg 9 2 kg Gross weight approx 4 8 kg approx 5 3 kg approx 6 0 kg approx 2...

Страница 14: ...by placing the air entrainment meter on a vibrating table Perform the compacting in accordance with the instructions given in EN 123507 Luftgehaltsdruckausgleichsverfahren air content pressure compens...

Страница 15: ...and 1 litre TESTING air entrainment meter Adjust by making one complete turn of the hooks of the clamps For the 5 litre 7 litre and 8 litre TESTING air entrainment meters In making precision adjustmen...

Страница 16: ...ave caused the black pointer to come to rest above the red marking next to the zero point In this case pump up the air entrainment meter again until the black pointer is below the red marking Note Aft...

Страница 17: ...oncrete may get into the pressure chamber After pressure compensation the CORRECTION button must not be pressed under any circumstances as otherwise sample material will flow through the channels into...

Страница 18: ...evice The initial pressure that applies to each device has already been set and marked by the red marking pointer during factory testing before each air entrainment meter is shipped to its users For p...

Страница 19: ...r contains no more bubbles it is essential that the water continuously flows through the air entrainment meter 7 Now close both of the ball shut off valves A and B 8 Turn the ball headed knob to the l...

Страница 20: ...t in touch with After Sales Service of the manufacturer His company will have to test and repair the air entrainment meter as necessary 4 3 Calibration From time to time it is necessary to check the a...

Страница 21: ...capacity of the test pot by measuring the mass of water that it contains 2 First weigh the test pot together with a transparent plate that covers the top surface of the pot 3 Then fill the pot up to t...

Страница 22: ...g or 100 g or 250 g or 350 g or 400 g of water 11 Carefully open the right ball shut off valve B to allow the pressure to be released from the test pot 12 Close both the ball shut off valves 13 Use t...

Страница 23: ...00 750 g 1 litre TESTING model no 1 0335 Since 100 g of water was taken out of the test pot and the pot contains a water mass of 1000 g this amount of water removed is 10 by volume This value must be...

Страница 24: ...nitial position See Section 7 Calibration instructions image 4 19 Remove the calibration tubes Empty the test pot and whip out the air entrainment meter until it is dry 20 Your air entrainment meter i...

Страница 25: ...he top of the test pot Follow the instructions for the use of the air entrainment meter 6 After sales service and spare parts A great deal of care has been taken to ensure that this Operating Manual i...

Страница 26: ...Feuerherdt GmbH Motzener Str 26b DE 12277 Berlin Germany Tel 49 30 710 96 450 Telefax 49 30 710 96 45 98 www testing de info testing de 6 4 Disposal and recycling These air entrainment meters be disp...

Страница 27: ...1 0335 A2 02 2 Quick release latch complete 2 x screws each 10 1 0335 A4 1 Clamping stud complete O rings nuts tube fitting 11 1 0335 A6 1 Pressure gauge complete Tube fitting O ring 12 1 0335 A7 K 1...

Страница 28: ...ment Meters 0 5 litre model TESTING 1 0334 0 75 litre model TESTING 1 0337 1 litre model TESTING 1 0335 5 litre model TESTING 2 0332 7 litre model TESTING 2 0337 8 litre model TESTING 2 0334 Page 28 o...

Страница 29: ...1 0335 A2 02 2 Quick release latch complete 2 x screws each 10 1 0335 A4 1 Clamping stud complete O rings nuts tube fitting 11 1 0335 A6 1 Pressure gauge complete Tube fitting O ring 12 1 0335 A7 K 1...

Страница 30: ...ment Meters 0 5 litre model TESTING 1 0334 0 75 litre model TESTING 1 0337 1 litre model TESTING 1 0335 5 litre model TESTING 2 0332 7 litre model TESTING 2 0337 8 litre model TESTING 2 0334 Page 30 o...

Страница 31: ...0335 A2 02 2 Quick release latch complete 2 x screws each 10 1 0335 A4 1 Clamping stud complete O rings nuts tube fitting 11 1 0335 A6 1 Pressure gauge complete Tube fitting O ring 12 1 0335 A7 K 1 H...

Страница 32: ...ment Meters 0 5 litre model TESTING 1 0334 0 75 litre model TESTING 1 0337 1 litre model TESTING 1 0335 5 litre model TESTING 2 0332 7 litre model TESTING 2 0337 8 litre model TESTING 2 0334 Page 32 o...

Страница 33: ...uick release latch complete 2 ea screws and spring 10 2 0334 A4 1 Clamping stud complete O rings nuts hose fittings 11 2 0332 A6 1 Pressure gauge Tube fittings O ring 12 2 0334 MS 1 Spare parts kit fo...

Страница 34: ...ment Meters 0 5 litre model TESTING 1 0334 0 75 litre model TESTING 1 0337 1 litre model TESTING 1 0335 5 litre model TESTING 2 0332 7 litre model TESTING 2 0337 8 litre model TESTING 2 0334 Page 34 o...

Страница 35: ...uick release latch complete 2 ea screws and spring 10 2 0334 A4 1 Clamping stud complete O rings nuts hose fittings 11 2 0337 A6 1 Pressure gauge Tube fittings O ring 12 2 0334 MS 1 Spare parts kit fo...

Страница 36: ...ment Meters 0 5 litre model TESTING 1 0334 0 75 litre model TESTING 1 0337 1 litre model TESTING 1 0335 5 litre model TESTING 2 0332 7 litre model TESTING 2 0337 8 litre model TESTING 2 0334 Page 36 o...

Страница 37: ...k release latch complete 2 ea screws and spring 10 2 0334 A4 1 Clamping stud complete O rings nuts hose fittings 11 2 0334 A6 1 Pressure gauge Tube fittings O ring 12 2 0334 MS 1 Spare parts kit for t...

Страница 38: ...ment Meters 0 5 litre model TESTING 1 0334 0 75 litre model TESTING 1 0337 1 litre model TESTING 1 0335 5 litre model TESTING 2 0332 7 litre model TESTING 2 0337 8 litre model TESTING 2 0334 Page 38 o...

Страница 39: ...5 litre model TESTING 1 0334 0 75 litre model TESTING 1 0337 1 litre model TESTING 1 0335 5 litre model TESTING 2 0332 7 litre model TESTING 2 0337 8 litre model TESTING 2 0334 Page 39 of 42 pages 7...

Страница 40: ...ment Meters 0 5 litre model TESTING 1 0334 0 75 litre model TESTING 1 0337 1 litre model TESTING 1 0335 5 litre model TESTING 2 0332 7 litre model TESTING 2 0337 8 litre model TESTING 2 0334 Page 40 o...

Страница 41: ...ed past the red marking Please do not pump any further Too much pressure may cause damages inside of the device or at the pressure gauge After the operator has pressed the Test button he or she must n...

Страница 42: ...ed guidelines as well as the additional applied guidelines following including any of the amendments thereto which are in force at the time of the declaration The following additional EU Directives ha...