Testboy TB 30 Скачать руководство пользователя страница 4

Information 

Testboy

®  

TB 30 

Information 

Safety information 

 

 

WARNING 

Sources of danger include for example, mechanical parts, which may cause serious 

personal injury.  

Objects are also at risk (e.g. damage to the instrument). 

 

 

WARNING 

An electric shock can result in death or serious personal injury and endanger the 

function of objects (e.g. damage to the instrument). 

 

 

WARNING 

Never point the laser beam towards eyes directly or indirectly via reflective surfaces. 

Laser radiation can cause irreparable damage to the eyes. The laser beam must be 

deactivated when conducting measurements close to people. 

 

General safety information 

 

 

WARNING 

Unauthorised modification and / or changes to the instrument are not permitted, for 

reasons of safety and approval (CE). In order to ensure safe and reliable operation 

of the instrument, you must always comply with the specifications of the safety in-

structions, warnings and the section "Intended use". 

 

 

WARNING 

Comply with the following specifications before using the instrument: 

|

 

Avoid operating the instrument near to electric welding equipment, induction 

heaters or other electromagnetic fields. 

|

 

After abrupt temperature fluctuations, the instrument must be allowed to adjust to 

the new ambient temperature for approx. 30 minutes before using it, in order to 

stabilise the IR sensor. 

|

 

Do not expose the instrument to high temperatures for a long period of time. 

|

 

Avoid dusty and humid environments. 

|

 

Measuring instruments and their accessories are not toys, and must be kept out 

of the reach of children! 

|

 

When working in commercial facilities, comply at all times with the specifications 

of the accident prevention regulations for electrical systems and equipment as 

established by the employer's liability insurance association. 

 

Содержание TB 30

Страница 1: ...Testboy TB 30 Version 1 5...

Страница 2: ...Testboy TB 30 Operating instructions 3 Testboy TB 30 Instrucciones de empleo 10...

Страница 3: ...contents Testboy TB 30 3 ENGLISH Table of contents Information 4 Operation 7 Use 7 Search mode 7 Test mode A 7 Test mode B Fehler Textmarke nicht definiert GFCI Test 8 Replacing the battery 8 Technica...

Страница 4: ...reliable operation of the instrument you must always comply with the specifications of the safety in structions warnings and the section Intended use WARNING Comply with the following specifications...

Страница 5: ...the safety instructions Any warranty claim expires in such cases An exclamation mark in a triangle indicates safety instructions in the operating instructions Read the instructions through before comm...

Страница 6: ...ally obliged battery law to return all used batteries disposal in the normal domestic waste is prohibited Batteries containing contaminant material are labelled with this symbol indicating that they m...

Страница 7: ...its function When the trans mitter signal is received the standby LED 4 flashes and the buzzer sounds Working in the fuse box locate the appendant circuit breaker by setting the sensitivity to maxi mu...

Страница 8: ...to be connected to the socket When the GFCI button is pressed for at least 8 seconds the LEDs 1 will be turned off after releasing the GFCI button If the circuit did not reset the GFCI button either t...

Страница 9: ...Voltage range 90 120 V AC Frequency range 50 60 Hz Power supply 9 V Block 6LR61 Operating temperature 5 C 40 C 41 F 104 F Storage temperature 20 C 60 C 4 F 140 F Dimensions 192 x 54 x 37 mm receiver...

Страница 10: ...ndice Indicaciones 11 Manejo 14 Manipulaci n 14 Modo de b squeda 14 Modo de comprobaci n A 14 Modo de comprobaci n B Fehler Textmarke nicht definiert Comprobaci n del GFCI diferencial 15 Cambio de pil...

Страница 11: ...uenta propia en el instrumento A fin de garantizar un funcionamiento seguro del instrumento es imprescindible cumplir las indicaciones de seguridad las notas de advertencia y el cap tulo Uso previsto...

Страница 12: ...es ocasionados por la manipulaci n inadecuada o por el incumplimiento de las indicaciones de seguridad no asumimos ninguna responsabilidad En estos casos queda anulado cualquier derecho por garant a U...

Страница 13: ...s por esta directiva llevan este logotipo Eliminaci n de pilas usadas Usted como consumidor final est obligado por ley a retornar todas las pilas y bater as usadas ley sobre pilas Est prohibido desech...

Страница 14: ...que el receptor al emisor preparado para operar para comprobar que funciona correctamente Cuando se recibe la se al del emisor modo de b squeda el LED de disponibilidad 4 parpadea y el vibrador emite...

Страница 15: ...ingeniero el ctrico profesional Si el bot n funciona presione el bot n en el enchufe El trans misor A debe estar conectado a la toma de corriente Cuando se presiona el bot n GFCI durante al menos 8 se...

Страница 16: ...CA Gama de frecuencia 50 60 Hz Suministro de corriente Pila de 9 V 6LR61 Temperatura de servicio 5 C 40 C 41 F 104 F Temperatura de almacenamiento 20 C 60 C 4 F 140 F Dimensiones 192 x 54 x 37 mm rece...

Страница 17: ...Datos t cnicos Testboy TB 30 17 ESPA OL...

Страница 18: ...Testboy GmbH Tel 0049 0 4441 89112 10 Elektrotechnische Spezialfabrik Fax 0049 0 4441 84536 Beim Alten Flugplatz 3 D 49377 Vechta www testboy de Germany info testboy de...

Отзывы: