- 17 -
Resistance:
RANGE
RESOLUTION
ACCURACY
200
Ω
0,1
Ω
over-range protection: 400 V DC/AC
± 1% + 5 digits
2 k
Ω
0.001
k
Ω
20 k
Ω
0.01
k
Ω
± 1% + 5 digits
200 k
Ω
0.1
k
Ω
2 M
Ω
0.001
M
Ω
20 M
Ω
0.01
M
Ω
± 1.8% + 5 digits
Measurement voltage: 0.25 V, over-range protection: 400 V AC/DC < 30 s
DIODE Test:
RANGE RESOLUTION
FUNCTION
Displays
the
0.001 V
forward voltage drop
Forward biasing current: approx. 0.6 mA, backward voltage: approx. 1.5 V,
Over-range protection: 400 V AC/DC < 30 s
CONTINUITY TEST:
RANGE FUNCTION
◦
))
The integrated buzzer signals
signals continuity up to 50
Ω
Measuring-circuit voltage: approx. 0.5 V, over-range protection: 400 V AC/DC
< 30 s
4. Application description
DC VOLTAGE MEASUREMENT
Set the selector switch to measurement range V=.
Insert the black test lead into the ‘COM’ socket and the red test lead into the right-
hand socket. Using the test probes, touch the test points of the test object.
The multimeter automatically searches for the most suitable measurement range.
Read measurement value on the display.