background image

LanScaper

TM

4.4 DHCP On/Off -

4.5 MAC add -

4.6 Units-Feet/Meters -

ARP received

DHCP Request -

Attempt -

Successful -

Find Active Link -

Link Found -

Link Not Found

Link word Err -

Lost Link -

This is a simple on-off selection made using the SEL button. The last

displayed state is the selected state. DHCP is a protocol negotiation used to automatically
configure the IP parameters of the LanScaper™ on a specific LAN segment. With DHCP On, the
next time the PING test is started, the tester will request IP parameters it needs for LAN
communication from a DHCP server on that LAN segment. If a response from a server is received,
the tester will configure itself with the acquired parameters and start to PING. Note that the only IP
parameter not received from the host is the Target IP address, which is always manually entered. If
no response is received, the tester cannot do any PINGing on that LAN. In that case, the PING
setup must be manually entered, and the DHCP Off state must be selected. The next PING test will
then attempt to communicate with the manually entered parameters. When used as a source for
PINGs to another LanScaper™ in the Validator mode, the PING Generator LanScaper™ must be in
DHCP Off (manual) mode.

This is a display-only of the factory-set Media Access Control number for the

specific LanScaper™ unit. All Ethernet-interfaced devices must have a universally-unique identifier
to be used as their address. This information is provided as a convenience to the user.

This is a simple selection made with the SEL button to choose whether the

tester displays the cable length it measures in feet or meters. The length constant is converted to
the new units.

- In Validate Link mode, this status shows that the tester has detected another active

LanScaper™ trying to start a PING conversation. This status flashes for a few seconds while the
units negotiate an IP address they can use to PING each other.

In the PING test with DHCP On, the LanScaper™ displays this message on the

first line while it is trying to get the required information from a DHCP server. The second line
displays:

count of DHCP requests sent out, if this number continues to increment, no response

is being received.

Shows for a short time after the server responds to the request.

The tester is searching for incoming Link pulses while waiting to start an active

test. Flash Link LED and PING test modes need to be connected to an active network in order to
run. In these modes, this status is displayed while the tester is searching both the 1-2 and 3-6 pairs
for incoming Ethernet Link pulses. In the Validate Link mode, the LanScaper™ assumes an active
NIC configuration, generating Link pulses on the 1-2 pair. This allows another LanScaper™ to be
connected directly to it.

Status displayed while searching for Link pulses after an incoming signal has been

detected.

- Status displayed while searching for Link pulses and nothing has been detected.

The Link word captured by the LanScaper™ during Jack ID test from an attached

100Mbit Ethernet device decoded an unrecognized value. May indicate a cable problem or a
hardware problem with the connected device.

A test was active, after having found incoming Link pulses, but they stopped being

received. Possibly due to the cable being disconnected or the connected device being shut off.

5.0 STATUS AND ERROR MESSAGES FOR NETWORK TEST MODES

Содержание LanScaper NT700

Страница 1: ...LanScaper TM OPERATING INSTRUCTIONS...

Страница 2: ...test change the value of an option enter sub menus or move to the next screen Depending on context Mode Key Press CABLE for cable modes press NTWRK for network modes or press the center both at once...

Страница 3: ...Jack ID 3 2 2 Cable Test 3 2 3 Cable Length 3 2 4 Tone Generator 3 3 Network Test Modes 3 3 1 Flash Link LED 3 3 2 PING Test 3 3 3 Validate Link 4 0 SETUP MODE 4 1 Target Setup Sub Menu 4 2 PING Setu...

Страница 4: ......

Страница 5: ...d Skips the ID portion of the Jack ID test above 1 Connect one end of cable run to be tested to LanScaper Press CABLE button repeatedly until Cable Test is displayed twice if unit was off Press SEL bu...

Страница 6: ...2 Press NTWRK button repeatedly until PING Test is displayed on screen two presses when off Press SEL button to enter test Several status screens will be displayed while establishing a link and negot...

Страница 7: ...button will immediately end any currently running task and either begin the executing the first task of a new category cable or network or display the next mode in the same category waiting for a pre...

Страница 8: ...detected the second line will have a flashing x in that position and the specific short condition displayed on the third line If a split pair is detected those pin positions on the second line will b...

Страница 9: ...tion modes The address configuration mode is a setup option In either case a Target device must be selected in Setup and its IP address confirmed If the Target address is on the LAN segment as determi...

Страница 10: ...tester for it to be possible for them to communicate directly on the same LAN segment A good guess is to use an IP address different by just a few low order digits in the low order byte of the IP add...

Страница 11: ...ne The Target IP address can either be on the LAN segment or remote If the Target is on the LAN the status of the LanScaper Target conversation will be as described for the Router above In the off loc...

Страница 12: ...ll assume is not responding on the network it will not interfere with other devices on the LAN The PING Generator must be setup in DHCP Off mode and its manual IP configuration must be setup to addres...

Страница 13: ...on reserved IP addresses This is any address other than 0 0 0 0 or 224 255 x x x MyIP is edited in a similar fashion to the Target IP addresses described above The Router IP address is also edited in...

Страница 14: ...th it measures in feet or meters The length constant is converted to the new units In Validate Link mode this status shows that the tester has detected another active LanScaper trying to start a PING...

Страница 15: ...ame as the DNS Server IP address so the Target PING is automatically disabled The active Target IP address is the same as the Router IP address so the Target PING is automatically disabled The IP addr...

Страница 16: ...the correct pins at the other end of the cable While testing with a remote the wire map shows the pin numbers line 1 main line 2 remote A is a special case of a miswire in which the pair is wired to...

Страница 17: ...8 8 8 8 8 8 8 8 SHORT T568A B Passing Cable unshielded 1 not twisted with 2 3 not twisted with 6 Fig 6 1 Examples of Wiring Errors shielded 12345678S ID 12345678S ID 12345678 ID 12345678S ID 12345678S...

Страница 18: ...rature 0 to 50 C 32 to 122 F Storage temperature 30 to 80 C 20 to 176 F Humidity 10 to 90 non condensing 9V Alkaline battery typical times are for the full capacity of the battery used continuously in...

Страница 19: ...an be used with a straight through cable to connect a normal HUB port to the UPLINK port Ethernet physical wiring is done on a point point mechanism but an Ethernet network is a star network where any...

Страница 20: ...ound on and once it has determined that it only forwards traffic destined for that address to that port This allows for fewer collisions on the LAN by not re transmitting every packet on every port Mu...

Страница 21: ...ng PINGing the DNS server proves that the LanScaper can access a device on the WAN Router see below Internet Protocol Actually TCP IP Transmission Control Protocol Internet Protocol but commonly abbre...

Страница 22: ...munications which differentiates it from a HUB or switch A hardware box sold as a router will usually include a HUB or switch chip inside providing a convenient connection point for multiple Ethernet...

Страница 23: ...inspected by anyone other than Test Um authorized personnel In no event will Test Um Inc be liable for any incidental or consequential damages The LanScaper is designed and manufactured to provide tr...

Страница 24: ...Test Um Inc The Intelligent Test Solutions Company 805 383 1500 FAX 805 383 1595 www test um com 808 Calle Plano Camarillo CA 93012 TU9854 3 Rev A 2 03...

Отзывы: