Gossen MetraWatt DUSPOL expert 1000 Скачать руководство пользователя страница 1

02/ 2019 

DUSPOL

®

 expert 1000

 

U2

02/ 2019 

DUSPOL

®

 expert 1000

 

U1

D

D

exper

t

exper

t

exper

t

3 sec.

PE

N

L

230 V

AC

1000 V

DC

230 V

AC

PE

N

L

A

B

C

D

DUSPOL

®

 

exper

t 1000

M

L

K

1

2

3

4

5

6

7

8

9

J

D

 Bedienungsanleitung

 Operating manual

F

 Mode d‘emploi

E

 Manuel de instrucciones

 

ɂɧɫɬɪɭɤɰɢɹɡɚɟɤɫɩɥɨɚɬɚɰɢɹ

1iYRGNSRXåLWt]NRXãHþN\

Brugsanvisning

ȅįȘȖȓİȢȤȡȒıİȦȢ

H

+DV]QiODWLXWDVtWiV

I

,VWUX]LRQLSHUO¶XVR

N

 Bruksanvisning

*HEUXLNVDDQZLM]LQJ

,QVWUXNFMDREVáXJL

 

Instruc

ĠLXQLGH8WLOL]DUH

 

ɂɧɫɬɪɭɤɰɢɹɩɨɷɤɫɩɥɭɚɬɚɰɢɢ

 

ɢɧɞɢɤɚɬɨɪɚɧɚɩɪɹɠɟɧɢɹ

S

 Bruksanvisning

1

SRB

8SXWH]DUXNRYDQMH

 Kullanma Talimati

T

.-Nr

. 10079315.04 

02/ 2019

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Содержание DUSPOL expert 1000

Страница 1: ...anuel de instrucciones ɂɧɫɬɪɭɤɰɢɹ ɡɚ ɟɤɫɩɥɨɚɬɚɰɢɹ 1iYRG N SRXåLWt NRXãHþN Brugsanvisning ȅįȘȖȓİȢ ȤȡȒıİȦȢ H DV QiODWL XWDVtWiV I VWUX LRQL SHU O XVR N Bruksanvisning HEUXLNVDDQZLM LQJ QVWUXNFMD REVáXJL InstrucĠLXQL GH 8WLOL DUH ɂɧɫɬɪɭɤɰɢɹ ɩɨ ɷɤɫɩɥɭɚɬɚɰɢɢ ɢɧɞɢɤɚɬɨɪɚ ɧɚɩɪɹɠɟɧɢɹ S Bruksanvisning 1 SRB 8SXWH D UXNRYDQMH Kullanma Talimati T Nr 10079315 04 02 2019 www GlobalTestSupply com Find Quality Pr...

Страница 2: ... 2019 DUSPOL expert 1000 U6 02 2019 DUSPOL expert 1000 U4 02 2019 DUSPOL expert 1000 U3 D D D D PE N L 230 VAC exp ert L1 쇵 expert 1 sec H E J F G I K www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...

Страница 3: ... 5 Load connection with vibration motor WHUQDO FRQGXFWRU WHVW SKDVH LQGLFDWLRQ 7 Phase sequence test RQWLQXLW WHVW 9 Cable break detector 10 Measuring point illumination DWWHU UHSODFHPHQW 12 Technical data 13 General maintenance 14 Environmental protection 6DIHW LQVWUXFWLRQV During the use touch the tester at the insulated handles L1 7 and L2 8 only and do not touch the probe tips L1 2 and L2 3 Ch...

Страница 4: ...two values of internal impedance has passed a performance test of managing interference voltages and is within technical limits able to distinguish operating volt age from interference voltage and has a means to directly or indirectly indicate which type of voltage is present OHFWULFDO V PEROV RQ WKH GHYLFH Symbol Meaning Important documentation The symbol indicates that the guide described in the...

Страница 5: ...DWLRQ WR 3 HDUWK ILJXUH WHUQDO FRQGXFWRU WHVW SKDVH LQGLFDWLRQ JXUH Fully grasp the handles L1 7 and L2 8 in order to en sure a capacitive coupling to earth Apply the probe tip L2 3 to the system part to be tested During the single pole external conductor test phase in dication make absolutely sure not to touch the probe tip L1 2 and that it remains contactless I WKH UHG 쇵 K lights up on the displ...

Страница 6: ...9 SURWHFWLRQ FDWHJRU 3 1 9 1 ILUVW LQGH SURWHFWLRQ DJDLQVW DFFHVV WR GDQJHURXV parts and protection against solid impurities dustproof 5 second index protected against water jets The device can also be used in the rain max allowable Duty cycle 30 s max 30 seconds 240 s off EDWWHU PLFUR 5 9 weight approx 250g length of connecting cable approx 1 000 mm operating temperature and storage temperature r...