Cable Cubby 1202 and 1402 • Installation Guide

This guide provides instructions for an experienced technician to install and connect the 
Extron Cable Cubby 1202 and 1402.

T

he Cable Cubby units are furniture-mounted enclosures for cable access, 

connections, and AC power. Cables that are not in use can be stored out of the 
way while remaining connected to the presentation system.

NOTE:

  This product is intended for use only with Extron UL listed 

power modules (not included).

Planning

Check with local and state regulations before starting the installation

 

…

Ensure that the planned installation complies with national and local building and electrical codes.

 

…

Ensure that the planned installation complies with the Americans with Disabilities Act or other accessibility requirements.

Check all parts and equipment before installation

 

…

Ensure that all parts are present in each kit.

 

…

Ensure that necessary tools and equipment are available for the installation.

Kit Contents

1

2

4

8

1

2

1

2

6 (3/8

"

), 2 (1/4

"

)

12 (3/8

"

), 4 (1/4

"

)

1

2

1

2

8

16

Cable Cubby 1202

Cable Cubby 1402

#4-40 Module Screws

#6 Pan-head Mounting 

Screws and Star Washers

AAP Frame Plate

Cable Grommet Plate

Hole Plugs

Retractor Pin & Clip

Connectivity 

Bracket

#4-40 Module Screws

AAP Frame Plate

Cable Grommet 

Plate

Hole Plugs

Retractor 

Bracket

Retractor 

Pin & Clip

#6-32 Mounting 

Screws and Star 

Washers

Содержание Cable Cubby 1202

Страница 1: ...th local and state regulations before starting the installation Ensure that the planned installation complies with national and local building and electrical codes Ensure that the planned installation complies with the Americans with Disabilities Act or other accessibility requirements Check all parts and equipment before installation Ensure that all parts are present in each kit Ensure that neces...

Страница 2: ...space under the table for cables Allow at least 36 inches of cable loop for each cable see Routing and Connecting Cables on page 8 When installing Retractors in the Cable Cubby ensure that there is enough space for the Retractor assembly under the table or furniture see the Retractor dimensions in the images below or go to www extron com Retractor dimensions NOTE Shown with Cable Cubby 1202 enclos...

Страница 3: ...upée seulement par des artisans autorisés et qualifiés Faites attention à ne pas faire de marques sur le meuble et à ne pas l endommager Choose one of the following methods for cutting the hole Hand Router and Routing Template Jigsaw and Paper Cut Out Template CNC Wood Router If using a CNC wood router or other precise machinery use the exact cut out dimensions for your model see the table below V...

Страница 4: ...d for vertical or angular Retractor mounting in a Cable Cubby 1402 Option 3b Use this option for horizontal Retractor mounting in a Cable Cubby 1402 only Secure the grommet plate on the connectivity bracket using four of the provided module screws Insert cables through the bottom of the connectivity bracket and into the holes of the grommet plate Snap the included hole plugs into any unused holes ...

Страница 5: ...o close completely Use a screwdriver to secure the modules with the screws Insert the modules into the Cable Cubby 1 Secure the modules using four of the provided pan head mounting screws and star washers 2 12 5V 50 6 0H z 12 A M AX TO TA L TOP Cable Cubby 1202 WARNING Risk of Electric Shock To ensure proper electrical grounding use the provided 6 32 mounting screws with the star washers AVERTISSE...

Страница 6: ...ble CAUTION The flanged edges of the top of the surface enclosure are sharp These edges are also soft and may be easily nicked or bent Exercise caution when handling the enclosure to prevent personal injury or damage to the enclosure ATTENTION Les extrémités à brides du haut de la surface du boîtier sont aiguisées Ces extrémités sont aussi lisses et peuvent facilement être coupées ou pliées Soyez ...

Страница 7: ...re the clip on the pin Insert Retractors into the Retractor bracket Secure the locking screw on each Retractor Do not overtighten 2 1 4 3 p Pin Clip Angular Mounting Remove the enclosure screws as shown above then follow this step Horizontal Mounting See the Cable Retractor Series 2 Setup Guide available on the Extron website for additional steps Remove two enclosure screws one on each side from t...

Страница 8: ...e best location for the enclosure Choose a method for cutting the hole in the table Preparing the Cable Cubby page 3 5 Assemble connectivity modules page 3 Install the modules page 5 Mounting the Cable Cubby in the Table page 5 Mount the Cable Cubby flush with the table Adjust the side clamps under the table Installing Retractors page 7 Routing and Connecting Cables page 8 Routing and Connecting C...