11

Continuity Check

To Verify Continuity:

A continuity test ensures that all circuit connections are intact.  
1. Plug the Black test lead into the COM port and the Red test

lead into the + port.

2. Set the rotary switch to the              position.
3. Connect the test leads to the circuit to be measured.  The

beeper will sound within 100mS if the resistance of the cir-
cuit measured is lower than 100 Ohms.

4. In addition to the beeper, #61-701 and #61-702 have a LED

to verify continuity.

General Specifications
Display: 

3-1/2 digit LDC display

Polarity Indication:

Automatic, negative indicated, 
positive implied

Overrange Indication:

“OL” 

Low Battery Indication:

when the battery voltage 

drops below operating voltage

Auto Power Off:

Approx. 60 min.

Temperature Coefficient:

0.1 x (specified accuracy) / 
°F, <64°F or >82°F 

Power Requirements:

9V NEDA 1604 

Battery Life:

300 hours typical with alkaline 
(150 hours #61-702); 150 hours
typical with carbon zinc (75 
hours #61-702)

Installation Category:

IEC 1010-1, IEC1010-2-032, 
Cat III 600V (1000V for 
#61-703)

Maintenance

Battery Replacement:

When the multimeter displays         the battery must be
replaced.  Disconnect and unplug leads, turn meter off, and
remove the battery cover.  Replace the battery with a NEDA type
1064 9V battery.

Fuse Replacement:

(For #61-702)
Remove the battery cover and back case.  Replace the fuse with
a 0.1A 660V (6.3 x 32mm) fast blow fuse.

Lifetime Limited Warranty

This meter is warranted to the original purchaser against
defects in material or workmanship for the lifetime of the meter.
During this warranty period, IDEAL INDUSTRIES, INC. will, at
its option, replace or repair the defective unit, subject to verifi-
cation of the defect or malfunction.

This warranty does not apply to defects resulting from abuse,
neglect, accident, unauthorized repair, alteration, or unreason-
able use of the instrument.

Any implied warranties arising out of the sale of an IDEAL
product, including but not limited to implied warranties of mer-
chantability and fitness for a particular purpose, are limited to
the above.  The manufacturer shall not be liable for loss of use
of the instrument or other incidental or consequential damages,
expenses, or economic loss, or for any claim or claims for
such damage, expenses or economic loss.

State laws vary, so the above limitations or exclusions may not
apply to you.  This warranty gives you specific legal rights, and
you may also have other rights which vary from state to state.

C

US

Warning

To avoid electrical shock, remove test lead before opening the
cover. Repairs or servicing not covered in this manual should
only be performed by qualified personnel.

Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176

FAX 781.665.0780 - TestEquipmentDepot.com 