4

6. Max button

Press Max prior to a measurement to capture the maximum
reading displayed during the measurement. To clear the max
value, press the max button again, or press the reset button
(#61-700).

7. Rotary switch

Turn the rotary switch to the appropriate function and range
for the measurement.

8. COM port and + port

Plug the black lead into the com port and the red lead into 
the + port for VAC, VDC, Frequency, Resistance, and
Capacitance measurements and Diode and Continuity
checks.

WARNING!

1.  DO NOT UNDER ANY CIRCUMSTANCES EXCEED THESE

RATINGS:

• Voltage is not to exceed 600 Volts for #61-700, 

and #61-701

• Voltage is not to exceed 750VAC or 1000VDC for 

#61-702

• Resistance, function is not to be performed on circuits 

capable of delivering greater than 600 Volts (1000VDC/ 
750VAC #61-703).

• Frequency, Capacitance and Continuity functions 

are not to be performed on circuits capable of delivering 
greater than 500 Volts. 

2.  To avoid electrical shock hazards and/or damage to the

meter:

• Test NCV function on known live wire before using. 

(#61-701 and #61-702)

• Do not exceed the voltage ratings for the meter.  Use 

caution when measuring voltage.

• Do not use during electrical storms.  AC power sources

with inductive loads or electrical storms may result in
high voltage. High energy transients can damage meter
and present a dangerous shock hazard.

• Turn off power to the circuit or device being measured

before taking resistance and capacitance measurements.
Fully discharge all capacitors before measuring.

The test lead can also be used to differentiate between the
hot and neutral.  Insert the rod test lead into the + port and
snap it into the test probe holder.  Press the NCV button and
insert the probe into each slot of the outlet.  The beeper will
only beep on the hot side of the outlet.

2. Test probe holder

Use the single test probe holder to make voltage testing easy.

3. Indicator lights (#61-701 and #61-702)

HI-V

High voltage indicator

In any VAC/VDC range when a voltage greater than 30V 
is touched, the beeper will beep,  and the red Hi-V LED 
will blink.

In addition to the LED and beeper, the 61-702 will shake
when connected to high voltage. Even if the LED can’t be
seen, or the beeper can’t be heard the shake can be felt.

NCV

Non-contact voltage indicator

Continuity indicator

CP

Clean power indicator (#61-702)

When the 60Hz AC power is clean, the green LED will be 
on. If the meter is connected to AC power, and the green
LED is not on, the circuit has more than 5% (±2%) total
harmonic distortion (nominal). Investigation with special-
ized equipment may be necessary.  Sensitivity:  20VAC on
200VAC range; 90V on 750VAC range.

4. Hold button

Press hold button during measurement to capture the value.
To clear the held value, press the hold button again, or
press the reset button. (#61-700)

5. NCV button (#61-701 and #61-702) or Reset button

(#61-700)

Press the NCV button on the #61-701 and #61-702 to test
for non-contact voltage.  On the #61-700, this is a reset
button to reset the hold and max values.