background image

TI1550 12-24-UAV GPU

19

3

Operating Procedures

3.11 – Regulated 14.25 / 28.5 Vdc Ground Power

Connecting DC Power Cable To Unit

Line up  the DC plug with the receptacle.  Push forward while rotating the T-handle one full turn clockwise. 

Ensure DC power cable plug is fully seated into the GPU’s DC Battery Receptacle.  The unit is now ready to 

safely transfer power.

Figure 3.11.1 Attaching DC Power Cable to GPU

WARNING

Do not allow Alligator Clips to touch when connecting to DC Power.

Содержание TI1550

Страница 1: ...uilt Smart Proven Tough Power Anytime Anywhere Tesla Industries Inc 101 Centerpoint Blvd New Castle DE 19720 302 324 8910 Phone 302 324 8912 Fax www teslaind com Tesla TI1550 12 24 UAV GPU User Manual...

Страница 2: ...y or death by electrical shock Any attempts to open or examine the inside of the TI1550 12 24 UAV GPU via a tool or device borescope probe etc can result in unit failure and or injury by electrical sh...

Страница 3: ...e Dry chemical CO2 or water spray Special Fire Fighting Procedures Cool GPU MPU exterior to prevent rupture Acid mists and vapors in a re are toxic and corrosive Unusual Fire and Explosion Hazards Hyd...

Страница 4: ...illable batteries must be packed according to IMDG Packing Instruction P003 This means shipping papers need not show proper shipping name hazard class UN num ber and packing group Hazardous labels are...

Страница 5: ...9 2 9 AC Input Connector 9 2 10 24 Volt Output Connector 10 2 11 24 Volt Output Control Breaker 10 2 12 12 Volt Output Connector 10 2 13 Input Voltage Selector Switch 11 2 14 Push to Test Button and L...

Страница 6: ...tion Questions 28 6 3 Basic Troubleshooting 29 30 Section 7 Performance Data 31 7 1 Purpose 31 7 2 General 31 7 3 Data Basis 31 7 4 Specific Conditions 31 7 5 General Conditions 31 7 6 Temperature Con...

Страница 7: ...hrenheit dc Direct Current EFF Efficiency ft Feet FWD Forward GPU Ground Power Unit Hr Hour Hz Hertz kg Kilograms kHz Kilohertz kW Kilowatts LED Light Emitting Diode max Maximum M megaohm min Minimum...

Страница 8: ...ard WARNING Indicates a condition operating procedure or practice which if not adhered to could result in serious injury or death CAUTION Indicates a condition or operating procedure which if not stri...

Страница 9: ...ser or the unit is wet while the operating unit is connected to a power source Be sure to disconnect ac power from the ac source if the unit has come into contact with water If AC Input Circuit Breake...

Страница 10: ...ing any fuel handling operation Power output is restricted to dc power only 1 5 Extreme Environments CAUTION Unit Damage Potential The unit is equipped with a charger temperature switch that automatic...

Страница 11: ...tputs can deliver up to 1500 peak amps The unit s high capacity power cells and circuitry are encased in a rugged enclosure This internal circuitry incorporates an intelligent recharging system that a...

Страница 12: ...Output Connector 4 Provides 24 Vdc to 28 5 Vdc 25 A 50 A peak 24 Volt Capacity Meter 5 Indicates the 24V battery charge state power output status 12 Volt Output Connector 6 Provides 12 Vdc to 14 25 Vd...

Страница 13: ...rechargeable battery power without ac 12 Volt Output 1500 peak starting amps 20 amps continuous 14 25 Vdc when plugged into ac power 43 amp hours 797 watt hours with ac power 23 amp hours 512 watt hou...

Страница 14: ...internal cooling system will efficiently regulate unit temperature regardless of load At room temperature 77 F the exhaust air will not exceed the ambient temperature by more than 5 F In more extreme...

Страница 15: ...erated in both the horizontal Figure 2 7 1 and vertical Figure 2 7 2 positions as shown Make sure that the airflow is not obstructed from air intake Figure 2 7 3 and outlet Figure 2 7 4 Figure 2 7 1 V...

Страница 16: ...plug ac line cord on military unit 1 2 Wait for a minimum of 60 seconds 2 3 Reset breaker by pressing red button 3 4 Reconnect ac and dc connections to the unit Plug in ac line cord on military unit 4...

Страница 17: ...24 Vdc output When pressed in it provides power to the 24 Vdc output connector Pulling it out will disconnect power If the current draw exceeds 50 amps the breaker will trip 2 12 12 Volt Output Conne...

Страница 18: ...the screw Overtightening will damage the Selector Shield 2 13 Input Voltage Selector Switch The Input Voltage Selector Switch allows the unit to operate safely within the expected voltage range of eit...

Страница 19: ...Without ac power input or dc power output simply press the Push to Test button on the faceplate 2 and hold for approximately 2 to 3 seconds At this time the LED bar graph should light up indicating t...

Страница 20: ...ting Procedures 3 1 Operating Procedures This section deals with normal procedures and includes all steps necessary to ensure safe and efficient operation of the unit NOTE When the unit is not in use...

Страница 21: ...ture stabilization the unit must be placed in an environment with a temperature below 38 C 100 F for 1 hour WARNING Operating any electrical equipment in the presence of moisture creates possible safe...

Страница 22: ...possible safety hazards and or potential for equipment damage Every effort has been made within the scope of existing technology to prevent foreseeable safety hazards and make the unit moisture resis...

Страница 23: ...r shorts to detect any problems with the unit To do so you will need to set your multimeter to measure or resistance You can test to see if both DC Output terminals are isolated from the chassis groun...

Страница 24: ...wn in Figure 3 8 8 Next place the negative probe black on the negative post of the DC Output Connector mark with the symbol The multimeter display should read approximately 13 5 Vdc 0 5 Vdc with power...

Страница 25: ...tructed from air intake and outlet See Section 2 6 3 Check that all connections are secure and free from water 4 Figure 3 9 1 TI1550 12 24 UAV GPU 3 10 Transporting Unit The TI1560 can be carried for...

Страница 26: ...plug with the receptacle Push forward while rotating the T handle one full turn clockwise Ensure DC power cable plug is fully seated into the GPU s DC Battery Receptacle The unit is now ready to safe...

Страница 27: ...tage for powering avionics and lighting on most aircraft The GPU s ac to dc converter produces continuous amps of dc power depending on the size of the system CAUTION Unplug AC power cord before start...

Страница 28: ...even if it is at Full Charge The unit will not overcharge or overheat If you received this manual with a new GPU When the Unit is fully charged the LED indicator should show a single steady green bar...

Страница 29: ...he unit to be recharged from the vehicle once the engine is started and the starter generator is running This feature will enable you to start multiple vehicles without reconnecting to ac power if the...

Страница 30: ...be damaged if recharged by NiCad or Lithium Ion battery chargers Power cells should only be charged by either the TI1550 12 24 UAV GPU s internal charger and the ac power cord furnished with the equi...

Страница 31: ...to remove dust dirt etc Protect Cables from Damage Do not cut crush or drag the input or output power cables when handling the unit Always inspect cables prior to use If no damage is evident proceed...

Страница 32: ...quest Form Seal the crate on all sides and return it to Tesla at the address listed below Please contact Tesla Customer Service at 302 324 8910 with any questions or concerns TESLA INDUSTRIES INCORPOR...

Страница 33: ...Start anywhere you travel ensuring that you will always have power 4 How much power will my Turbo Start provide Depending on the system the Turbo Start will provide anywhere from 1500 to 3500 peak sta...

Страница 34: ...I get my Turbo Start serviced Contact Tesla We can be reached at 302 324 8910 Ask for customer service You can also email us at tesla1 teslaind com Once we receive the unit at our facility we will exa...

Страница 35: ...always running when I am plugged into ac power Constant cooling fan operation ensures proper and consistent ventilation of the unit 6 Why does the cooling fan slow down Cooling fan rpm varies for bet...

Страница 36: ...m ac outlet AC line cord is damaged or bad A Is ac line cord fully plugged into unit B and wall outlet AC circuit breaker has been tripped C No ac power at outlet D Do a continuity test on the ac line...

Страница 37: ...t put out 28 5 volts dc power Unit is not plugged in A Plug unit into ac power source to A maintain 28 5 Stand alone Vdc is 24 Volts B unplugged 9 Unit stand alone voltage is less than 23 volts Cells...

Страница 38: ...so given The data provided generally are based on one of three categories Derived From Actual Controlled Testing Controlled test data obtained on a similar unit type A Calculated Data Data based on te...

Страница 39: ...50 8 13 0 8 6 20 0 68 0 53 0 127 4 45 0 49 0 12 0 10 4 21 0 69 8 54 0 129 2 44 0 47 2 11 0 12 2 22 0 71 6 55 0 131 0 43 0 45 4 10 0 14 0 23 0 73 4 56 0 132 8 42 0 43 6 9 0 15 8 24 0 75 2 57 0 134 6 4...

Страница 40: ...TI1550 12 24 UAV GPU 33 7 Performance Data Maximum Output Current TI1550 12 24 UAV GPU 12 Vdc Output Voltage 7 7 Output Voltage 7 8 Maximum Output Current...

Страница 41: ...TI1550 12 24 UAV GPU 34 7 Performance Data 7 9 12 Vdc Output Loading Curves...

Страница 42: ...TI1550 12 24 UAV GPU 35 7 Performance Data 7 9 24 Vdc Output Loading Curves cont d...

Страница 43: ...ice to find out more about our selection of cables Regular Line Cords TI25000 001 North American Line Cord TI25000 002 Italian Line Cord TI25000 003 Continental European Line Cord TI25000 004 Old Brit...

Страница 44: ...hrough the Tesla Customer Service TI2005 238 Cobra Aviation Plug TI2005 078 Cobra NATO Connector NSN 6130 01 523 1270 CL IX TI2005 251 DC Aviation Plug Positive Negative Contact TI2005 250 DC Aviation...

Страница 45: ...opean Line Cord Burma Now Myanmar 230 50 TI25000 005 United Kingdom Line Cord Burundi 220 50 TI25000 003 Continental European Line Cord Cambodia 220 50 TI25000 003 Continental European Line Cord Camer...

Страница 46: ...ord Guadeloupe 220 50 TI25000 003 Continental European Line Cord Guam 110 120 60 TI25000 001 North American Line Cord Guatemala 120 60 TI25000 001 North American Line Cord Guinea 220 50 TI25000 003 Co...

Страница 47: ...ean Line Cord Montseurrat 230 60 TI25000 005 United Kingdom Line Cord Morocco 220 50 TI25000 003 Continental European Line Cord Mozambique 220 50 TI25000 003 Continental European Line Cord Namibia W S...

Страница 48: ...I25000 004 Old British Line Cord Sweden 220 50 TI25000 003 Continental European Line Cord Switzerland 220 50 TI25000 006 Switzerland Line Cord Syria 220 50 TI25000 003 Continental European Line Cord T...

Страница 49: ...I16000 19 AND MUST BE ORDERED WITH THE ORIGINAL PROCUREMENT OF UNIT S UNIT S MAY BE RETURNED TO TESLA INDUSTRIES FOR A NOMINAL COST AND MODIFIED TO ALLOW OPERATION WITH THE UNIVERSAL AC LINE CORD KIT...

Страница 50: ..._______________________________________________________________________________________ Purchase Order ______________________________________________________________________________ Model ____________...

Страница 51: ...Tesla Industries Inc 101 Centerpoint Blvd New Castle DE 19720 USA Tel 302 324 8910 Fax 302 324 8912 9475 Double R Blvd Suite 2 Reno NV 89521 Tel 775 622 8801 Fax 775 622 8810 www teslaind com...

Страница 52: ...tput 1500 peak starting amps 20 amps continuous 14 25 Vdc when plugged into ac power 43 amp hours 797 watt hours with ac power 23 amp hours 512 watt hours of rechargeable battery power without ac 24 V...

Страница 53: ...14 7 amps 120 Vac 60 hz Recharging Rate 12 Vdc Output 24 Vdc Output from full discharge 74 minutes with 100 260 Vac power 60 minutes with 100 260 Vac power Weight 89 lbs 40 4 kg Technical Specificatio...