TI1500 GPU-12
21
4.1 – General
Although the TI1500 GPU-12 has been ruggedized and made weather resistant within the scope of unit’s
intended use, it is essential that good general care be taken to maintain unit in good operating condition and
to maximize unit’s operational life.
4.2 – After Use
Unit should be protected from environmental elements and man made hazards. Ideally unit should be secured
in a building or shed. Most importantly, unit shall be fully covered if stored while exposed to environmental
elements.
4.3 – Power Cell Recharge
NOTE
!
The TI1500 GPU-12 incorporates a backcharge feature that enables the unit
to be recharged from the vehicle once the engine is started and the starter/
generator is running. This feature will enable you to start multiple vehicles
without reconnecting to ac power if the GPU is allowed to backcharge for
approximately 30 seconds.
NOTE
!
Plug the TI1500 GPU-12 into ac power to keep the cells charged whenever
it is not in use, even if it is at Full Charge. The unit will not overcharge or
overheat.
Connect AC Power Cord to Unit
Ensure 120 or 240 Vac power cord is properly connected to an approved ac power supply. After approximately
5-8 seconds, ensure unit’s LED status indicator illuminates indicating power cell state of charge and cooling
fan is operating.
Any time the unit’s power cells are fully discharged the unit shall be recharged within 24 hours to prevent
performance degradation and ensure maximum life.
Section 4 – Post Operation
Figure 4.3.1 Connecting TI1500 GPU-12 to AC
Power Supply
Figure 4.3.2 AC North American Line Cord
NOTE
!
Check Input Voltage Selector Switch for proper setting.