8
ENG
Ventilation Of Room
The air needed for burning is received from room air and the gases emitted are given directly in room. For safe
operation of your product, good room ventilation is a precondition. If no window or room to be utilized for room
ventilation is available, additional ventilation should be installed. However, room has a door opening outside, it is
no needed to vent holes.
Figure 4
Figure 5
Room size
Ventilating opening
Smaller than 5 m³
min. 100 cm²
Between 5 m³ - 10 m³
min. 50 cm²
Bigger than 10 m³
no need
In basement or cellar
min. 65 cm²