FAULT STATUS :
In some cases controller checks events but can not find solutions, in this case controller decide to stop system
,for restart user must be turn off S1 (inverter input) switch and turn on again.
WARNING STATUS :
Some events recorded to log event file stays on LCD PANEL but UPS continues to work, these messages
named as warning messages, user can clear this messages by pressing ENTER key for 3 seconds.
These are:
•
A20 Boost charge alert
•
A6 Charger fault
•
A18 Batt capacity low
Shutdown Messages :
T-300P series UPS’s can operate interactive with operating system, by using some softwares you can send
commands to UPS from operating system .UPS takes this commands and produces some messages these are:
WAITING SHUTDOWN
:
Shutdown command is performed from operating system and UPS is waiting for
a certain delay for shutdown.
UPS SHUTDOWN
: UPS is in shutdown status
WAITING RESTART
: UPS is shutdown but it is waiting for a certain delay for restart
PAR.SHUTDOWN
: In parallel system the other UPS send shutdown command and UPS is in
shutdown status.
CANCEL SHUTDOWN
: Shutdown command is canceled.
Only operating system or a PC computer can send this commands.
If the shutdown command is performed during line failure UPS shutdowns and is the mains is okay UPS starts
again automaticly.
2.3 Menu Description
By using UP and DOWN function keys on front panel you can move on main menu functions ,when main menu
appears on LCD panel if you press ENTER key you can go to submenu item.
In submenu you can move by UP and DOWN keys ,if there is option on submenu item ,you can change options
by pressing PLUS and MINUS keys. If you press ENTER ket the option is valid.
MEASURES submenu
LD% (output load percentage)
OPV (output voltages)
FREQU (output frequency)
IPV (input voltages)
BYP (bypass source voltages)
BATT (battery voltage and current)
...... etc
SAMPLE menu selection:
If you want to go measures menu use UPS and DOWN keys find MEASURES MENU, press ENTER key ,now
you can move on measures menu subitems by UP and DOWN keys.
At the end of sub menus ENTER EXIT is located, during this message if you press ENTER key you can go back
main menu.
At ALARMS MENU you can see LOG HISTORY, log events are recorded with event time and date.
PASSWORD
Menu is located for service purposes. This menu is developed for only adjustment.