FF-MM-326-REV -01
Page 3
Operation and Maintenance Guide SDP 25 Metal Series
Pump Nomenclature
XX
XX
XX
X
X
X
Air Valve Type
Pump Size
Material of Construction
Material of
Diaphragm
Bolted or
Clamped
Threading on Inlet
and Outlet
DP - Classic
ADP - Advanced
SDP - MaxFlo
06 - 1/4”
AL - Aluminium
SS - Stainless Steel 316L
PP - Polypropylene
CI - Ductile Iron
B - Nitrile
N - Neoprene
S - Santoprene
T - PTFE
V - Viton
H - Hytrel
B - Bolted
C - Clamped
R- NPT
G - BSPT
P - BSPP
F - Flanged
12 - 1/2”
15 - 1/2”
25 - 1”
40 - 1 - 1/2”
50 - 2 “
75- 3”
100 - 4”
Operating and Safety Instruc-
tions
Warning: Static Electricity
Static sparks can cause explosion result-
ing in severe injury or death.
Ground the pump and the pump connections
like hoses and containers into which or from
the fluid is being transferred. Connect the
grounding wire to any bolt on the pump.
Check continuity of electrical path to ground
at regular intervals.
Consult local building and electrical codes for
grounding requirements where needed.
Use hoses containing a grounding wire.
Warning: Pump Exhaust
In case of a diaphragm failure, fluid be-
ing pumped may spray out from the exhaust
of the pump. This may cause severe injury
depending on the fluid being pumped.
If the fluid is hazardous, pipe away the ex-
haust to a safe remote location using a gener-
ous diameter pipe preferably with a ground-
ing arrangement, and refit the muffler at the
end of this arrangement.
Always wear safety glasses while in the vicini-
ty of an operating pump.
Warning: Overpressure / Haz-
ardous Pressure
Do not exceed the max supply air pressure of
125 PSI.
Make sure all connected hoses and pipelines
are rated to operate safely with the pressures
generated by pump of 125 PSI.
Do not open or handle pump or hoses while
pressurized.
Disconnect air supply line and relieve pres-
sure from the system by carefully opening
discharge and supply lines.
Warning: Hazardous Materials
Do not move a pump that contains haz-
ardous fluids trapped inside it. Please observe
prescribed handling and safety codes. Drain
the pump safely, by turning it upside down
and collecting the fluid safely, before moving
the pump.
Warning :Explosion
Please check compatibility of fluids
intended to be handled with the materials of
construction of the pump. Severe reactions
and explosions may occur if materials are
incompatible. Caution: Chemical
compatibility